Schneider LRD365L technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSysTeSys Deca |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 70 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Network type | DCAC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7Vibrations: 4 gn conforming to IEC 60068-2-6 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACDNV-GLRMRSEU-RO MRLROS (Lloyds register of shipping)UKCA |
| Permissible current | 3 A at 120 V AC-15 for signalling circuit0.22 A at 125 V DC-13 for signalling circuit |
| Depth | 123 mm |
| Width | 55 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 48…65 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 5 N.m - on EverLink BTR screw connectors |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.375 kg |
Overview
Technical Specifications of Schneider Relay For DC/AC Network LRD365L: Obtain a Quote for Schneider Relay For DC/AC Network LRD365L at economical prices. Specifications Overview for LRD365L reveals device short name LRD, from the TeSysTeSys Deca range. The product, known as TeSys LRDTeSys Deca, is designed for reliable thermal protection in motor control applications. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 70 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance.
Datasheet
Schneider datasheetschneider-electric-lrd365l.pdfOther models in this series
Compare LRD365L with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD365L (this model) | TeSysTeSys Deca | 48…65 A | 6 kV | DCAC |
| LR2D3559 | TeSys | 48…65 A | 6 kV | DCAC |
| LRD086 | TeSysTeSys Deca | 2.5…4 A | 6 kV | DCAC |
| LRD126 | TeSysTeSys Deca | 5.5…8 A | 6 kV | DCAC |
| LRD1522 | TeSys | 17…25 A | 6 kV | ACDC |
| LRD33676 | TeSys | 95…120 A | 6 kV | ACDC |
| LRD1516 | TeSys | 9…13 A | 6 kV | DCAC |
| LRD318 | TeSysTeSys Deca | 12…18 A | 6 kV | DCAC |
| LRD325L | TeSysTeSys Deca | 17…25 A | 6 kV | ACDC |