Image for reference. Refer to the datasheet for exact dimensions.
LRD33676: Schneider Electric Motor Protection Solution
Schneider LRD33676, Electric Motor Protection Solution. Ensure reliability—request a quote from IndMALL today for efficient motor protection.
- Brand
- Schneider
- Model number
- LRD33676
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LRD33676 technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 123 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Network type | ACDC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACATEX INERISUKCA |
| Permissible current | 0.72 A at 500 V AC-15 for signalling circuit0.06 A at 440 V DC-13 for signalling circuit |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 2.2 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 95…120 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 9 N.m - on screw clamp terminals |
| Mounting support | PlateRail |
| Relay application | Motor protection |
| Net weight | 1 kg |
Overview
Technical Specifications of Schneider Electric Motor Protection Solution LRD33676: Talk to Our Engineer for Schneider Electric Motor Protection Solution LRD33676 with exclusive offers. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 123 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The auxiliary contact composition includes 1 NO + 1 NC, and it features a thermal overload Class 10A conforming to IEC 60947-4-1. It supports both ACDC network types.
Datasheet
Schneider datasheetschneider-electric-lrd33676.pdfOther models in this series
Compare LRD33676 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD33676 (this model) | TeSys | 95…120 A | 6 kV | ACDC |
| LRD086 | TeSysTeSys Deca | 2.5…4 A | 6 kV | DCAC |
| LRD126 | TeSysTeSys Deca | 5.5…8 A | 6 kV | DCAC |
| LRD1522 | TeSys | 17…25 A | 6 kV | ACDC |
| LRD365L | TeSysTeSys Deca | 48…65 A | 6 kV | DCAC |
| LRD1516 | TeSys | 9…13 A | 6 kV | DCAC |
| LRD318 | TeSysTeSys Deca | 12…18 A | 6 kV | DCAC |
| LRD325L | TeSysTeSys Deca | 17…25 A | 6 kV | ACDC |
| LRD21L | TeSysTeSys Deca | 12…18 A | 6 kV | DCAC |