Image for reference. Refer to the datasheet for exact dimensions.
LR3D036: Schneider Overload Relay For Industrial Use
Schneider LR3D036, Overload Relay For Industrial Use. Ensure reliable motor control—ask IndMALL for pricing today and improve protection systems.
- Brand
- Schneider
- Model number
- LR3D036
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LR3D036 technical specifications
| Device short name | LR3D |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 66 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Network type | DCAC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACBVRINADNV-GLLROS (Lloyds register of shipping)ATEX INERISUKCA |
| Permissible current | 3 A at 120 V AC-15 for signalling circuit0.22 A at 125 V DC-13 for signalling circuit |
| Depth | 70 mm |
| Width | 45 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 0.25…0.4 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 2.3 N.m - on lugs-ring terminals M4 |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.124 kg |
Overview
Technical Specifications of Schneider Overload Relay For Industrial Use LR3D036: Talk to Our Engineer for Schneider Overload Relay For Industrial Use LR3D036 with exclusive offers. Core System Specifications of LR3D036 are device short name LR3D, from the TeSys range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 66 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The control type consists of a Red push-button: stopBlue push-button: reset.
Datasheet
Schneider datasheetschneider-electric-lr3d036.pdfOther models in this series
Compare LR3D036 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LR3D036 (this model) | TeSys | 0.25…0.4 A | 6 kV | DCAC |
| LR2D3557 | TeSys | 37…50 A | 6 kV | DCAC |
| LR2D3561 | TeSys | 55…70 A | 6 kV | ACDC |
| LR2D3563 | TeSys | 63…80 A | 6 kV | ACDC |
| LR3D01 | TeSys | 0.1…0.16 A | 6 kV | ACDC |
| LR3D04 | TeSysTeSys Deca | 0.4…0.63 A | 6 kV | ACDC |
| LR3D046 | TeSysTeSys Deca | 0.4…0.63 A | 6 kV | DCAC |
| LR3D066 | TeSysTeSys Deca | 1…1.6 A | 6 kV | ACDC |
| LR3D08 | TeSysTeSys Deca | 2.5…4 A | 6 kV | DCAC |