Image for reference. Refer to the datasheet for exact dimensions.
LR3D01: Schneider Electric Relay With Control Terminals
Schneider LR3D01, Electric Relay With Control Terminals. Protect motors—request a quote from IndMALL today for reliable motor control solutions.
- Brand
- Schneider
- Model number
- LR3D01
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LR3D01 technical specifications
| Device short name | LR3D |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 66 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Network type | ACDC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACBVRINADNV-GLLROS (Lloyds register of shipping)ATEX INERISUKCA |
| Permissible current | 3 A at 120 V AC-15 for signalling circuit0.22 A at 125 V DC-13 for signalling circuit |
| Depth | 70 mm |
| Width | 45 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 0.1…0.16 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 1.7 N.m - on screw clamp terminals |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.124 kg |
Overview
Technical Specifications of Schneider Electric Relay With Control Terminals LR3D01: Obtain a Quote for Schneider Electric Relay With Control Terminals LR3D01 at economical prices. Specifications Overview for LR3D01 reveals device short name LR3D, from the TeSys range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 66 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. Our commitment to better pricing and exceptional support sets us apart from other Competitors.
Datasheet
Schneider datasheetschneider-electric-lr3d01.pdfOther models in this series
Compare LR3D01 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LR3D01 (this model) | TeSys | 0.1…0.16 A | 6 kV | ACDC |
| LR2D3555 | TeSys | 30…40 A | 6 kV | DCAC |
| LR2D3557 | TeSys | 37…50 A | 6 kV | DCAC |
| LR2D3561 | TeSys | 55…70 A | 6 kV | ACDC |
| LR2D3563 | TeSys | 63…80 A | 6 kV | ACDC |
| LR3D036 | TeSys | 0.25…0.4 A | 6 kV | DCAC |
| LR3D04 | TeSysTeSys Deca | 0.4…0.63 A | 6 kV | ACDC |
| LR3D046 | TeSysTeSys Deca | 0.4…0.63 A | 6 kV | DCAC |
| LR3D066 | TeSysTeSys Deca | 1…1.6 A | 6 kV | ACDC |