Schneider LR2D3563 technical specifications
| Device short name | LR2D |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 100 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Network type | ACDC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSAEACDNV-GLLROS (Lloyds register of shipping)UKCA |
| Permissible current | 0.72 A at 500 V AC-15 for signalling circuit0.06 A at 440 V DC-13 for signalling circuit |
| Depth | 121 mm |
| Width | 75 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 2.2 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 63…80 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 9 N.m - on screw clamp terminals |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.535 kg |
Overview
Technical Specifications of Schneider Motor Protection For Industrial Applications LR2D3563: Mail Us for your needs in Schneider Motor Protection For Industrial Applications LR2D3563 with budget-friendly prices. The Main Technical Parameters of LR2D3563 include device short name LR2D, from the TeSys range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 100 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The control type consists of a Red push-button: stopBlue push-button: reset.
Datasheet
Schneider datasheetschneider-electric-lr2d3563.pdfOther models in this series
Compare LR2D3563 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LR2D3563 (this model) | TeSys | 63…80 A | 6 kV | ACDC |
| LR2D3522 | TeSys | 17…25 A | 6 kV | ACDC |
| LR2D3555 | TeSys | 30…40 A | 6 kV | DCAC |
| LR2D3557 | TeSys | 37…50 A | 6 kV | DCAC |
| LR2D3561 | TeSys | 55…70 A | 6 kV | ACDC |
| LR3D01 | TeSys | 0.1…0.16 A | 6 kV | ACDC |
| LR3D036 | TeSys | 0.25…0.4 A | 6 kV | DCAC |
| LR3D04 | TeSysTeSys Deca | 0.4…0.63 A | 6 kV | ACDC |
| LR3D046 | TeSysTeSys Deca | 0.4…0.63 A | 6 kV | DCAC |