Image for reference. Refer to the datasheet for exact dimensions.
Sick RLY3-OSSD400 Safety Relay
Mail Us for Sick Programmable Safety Relay RLY3-OSSD400, 1099971 at exclusive offers. Front connector with spring terminals, 12 A Total current.
- Brand
- Sick
- Model number
- RLY3-OSSD400
- Series
- RLY3 Series
- Product type
- Safety Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Sick RLY3-OSSD400 technical specifications
| Compatible sensor types | Safety sensors with OSSDs |
|---|---|
| Safety integrity level | SIL 3 (IEC 61508) |
| Category | Category 4 (ISO 13849-1) |
| Performance level | PL e (ISO 13849-1) |
| TM (mission time) | 20 years (ISO 13849-1) |
| Sensor monitoring | - |
| Restart interlock | - |
| Reset | - |
| External device monitoring (EDM) | ✔ |
| Connection type | Front connector with spring terminals |
| Inputs | 2 safety inputs |
| Outputs | 4 enabling current paths (safe), 1 feedback current path (for use as external device monitoring, not safe), 1 signaling current path (not safe) |
| Display elements | LEDs |
| Configuration method | - |
| Supply voltage VS | - |
| Residual ripple | - |
| Power consumption | ≤ 2.5 W (DC) |
| Input voltage HIGH | 24 V DC (11 V ... 30 V) |
| Input voltage LOW | 0 V DC (–3 V ... 5 V) |
| Input current | ≤ 60 mA |
| Test pulse width | ≤ 1 ms |
| Test pulse rate | ≤ 10 Hz |
| Response time | 12 ms |
| Type of output | N/O contacts, positively guided |
| Contact material | Silver alloy, gold flashed |
| Switching voltage | 10 V AC ... 230 V AC, 10 V DC ... 230 V DC |
| Switching current | 10 mA ... 6 A |
| Total current | 12 A |
| Overvoltage category | III (EN 60664-1) |
| Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
| Output voltage HIGH | - |
| Output voltage LOW | - |
| Input current (NPN) | - |
| Output current (PNP) | - |
| Output voltage | - |
| Test pulse interval | - |
| Dimensions (W x H x D) | 28 mm x 124.6 mm x 85.5 mm |
| Enclosure rating | IP20 (IEC 60529) |
| Ambient operating temperature | –25 °C ... +55 °C |
| Storage temperature | –25 °C ... +70 °C |
| Air humidity | ≤ 95 %, Non-condensing |
| Interference emission | According to IEC 61000-6-4 |
| Interference resistance | According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1 |
| Weight | 180 g |
Overview
The RLY3-OSSD400 is a reliable Sick Programmable Safety Relay designed for industrial automation systems requiring high-performance signal switching and monitoring. The relay is equipped with N/O positively guided contacts made from silver alloy, gold flashed , supporting 10 V to 230 V AC/DC switching at up to 6 A , making it ideal for high-current switching scenarios. The compact housing (dimensions: 28 mm x 124.6 mm x 85.5 mm ) is rated IP20 , suitable for protected enclosure use. Operating reliably in ambient temperatures from –25 °C to +55 °C and up to 95% humidity , the RLY3-OSSD400 is trusted across sectors such as packaging, robotics, and machine tool safety.
Datasheet
Sick datasheetrly3-ossd400-1099971.pdfOther models in this series
Compare RLY3-OSSD400 with similar models in the same series. See all 10 models on the RLY3 Series page.
| Model | Configuration method | Input current | Input current (NPN) | Output current (PNP) |
|---|---|---|---|---|
| RLY3-OSSD400 (this model) | - | ≤ 60 mA | - | - |
| RLY3-OSSD300 | Hard wired | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-EMSS100 | — | |||
| RLY3-TIME100 | Hard wired, DIP switch | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-MULT100 | Hard wired, DIP switch | ≤ 60 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD100 | - | ≤ 50 mA | - | - |
| RLY3-HAND100 | Hard wired | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD200 | — | |||
| RLY3-LOOP100 | Hard wired, DIP switch | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |