Image for reference. Refer to the datasheet for exact dimensions.
Sick RLY3-MULT100 Safety Relay
Ask for the Pricing of Sick Safety Sensor Relay RLY3-MULT100, 1100692 at affordable prices. Front connector with spring terminals, 24 V DC, 12 A.
- Brand
- Sick
- Model number
- RLY3-MULT100
- Series
- RLY3 Series
- Product type
- Safety Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Sick RLY3-MULT100 technical specifications
| Compatible sensor types | Safety sensors with OSSDs, Safety sensors with test input, Safety sensors with potential-free outputs, Safety pressure mats |
|---|---|
| Safety integrity level | SIL 3 (IEC 61508) |
| Category | Category 4 (ISO 13849-1) |
| Performance level | PL e (ISO 13849-1) |
| TM (mission time) | 20 years (ISO 13849-1) |
| Sensor monitoring | Discrepancy monitoring, Sequence monitoring, Cross-circuit detection |
| Restart interlock | ✔ |
| Reset | Automatic, Manual |
| External device monitoring (EDM) | ✔ |
| Connection type | Front connector with spring terminals |
| Inputs | 2 safety inputs,1 input for reset pushbutton or external device monitoring (EDM) |
| Outputs | 3 enabling current paths (safe), 2 application diagnostic outputs (not safe), 2 test pulse outputs (not safe) |
| Display elements | LEDs |
| Configuration method | Hard wired, DIP switch |
| Supply voltage VS | 24 V DC (16.8 V ... 30 V) |
| Residual ripple | ≤ 2.4 V |
| Power consumption | ≤ 2.5 W (DC) |
| Input voltage HIGH | 24 V DC (11 V ... 30 V) |
| Input voltage LOW | 0 V DC (–3 V ... 5 V) |
| Input current | ≤ 60 mA |
| Test pulse width | ≤ 1 ms |
| Test pulse rate | ≤ 10 Hz |
| Response time | Depends on the configured sensor type, for details see operating instructions |
| Type of output | N/O contacts, positively guided |
| Contact material | Silver alloy, gold flashed |
| Switching voltage | 10 V AC ... 230 V AC, 10 V DC ... 230 V DC |
| Switching current | 10 mA ... 6 A |
| Total current | 12 A |
| Overvoltage category | III (EN 60664-1) |
| Rated impulse withstand voltage Uimp | 6 kV (EN 60664-1) |
| Output voltage HIGH | ≥ Vs – 3 V |
| Output voltage LOW | ≤ 3 V |
| Input current (NPN) | ≤ 15 mA |
| Output current (PNP) | ≤ 120 mA |
| Output voltage | ≥ Vs – 3 V |
| Test pulse interval | Depends on the configured sensor type, for details see operating instructions |
| Dimensions (W x H x D) | 18 mm x 124.6 mm x 85.5 mm |
| Enclosure rating | IP20 (IEC 60529) |
| Ambient operating temperature | –25 °C ... +55 °C |
| Storage temperature | –25 °C ... +70 °C |
| Air humidity | ≤ 95 %, Non-condensing |
| Interference emission | According to IEC 61000-6-4 |
| Interference resistance | According to IEC 61326-3-1, According to IEC 61000-6-2, According to IEC 60947-5-1 |
| Weight | 160 g |
Overview
The RLY3-MULT100 Sick Safety Sensor Relay is a high-performance safety relay engineered for reliable signal switching in industrial safety applications. Operating on 24 V DC (16.8 V – 30 V) , the relay draws a maximum of 2.5 W , with ≤ 2.4 V ripple and input current of ≤ 60 mA . Its compact size ( 18 mm x 124.6 mm x 85.5 mm ), IP20 enclosure , and LED status indicators make it a space-saving, user-friendly addition to any safety system. The relay performs reliably across harsh industrial conditions, with ambient operating temperatures of –25 °C to +55 °C and humidity up to 95% .
Datasheet
Sick datasheetrly3-mult100-1100692.pdfOther models in this series
Compare RLY3-MULT100 with similar models in the same series. See all 10 models on the RLY3 Series page.
| Model | Configuration method | Input current | Input current (NPN) | Output current (PNP) |
|---|---|---|---|---|
| RLY3-MULT100 (this model) | Hard wired, DIP switch | ≤ 60 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD300 | Hard wired | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-EMSS100 | — | |||
| RLY3-TIME100 | Hard wired, DIP switch | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD400 | - | ≤ 60 mA | - | - |
| RLY3-OSSD100 | - | ≤ 50 mA | - | - |
| RLY3-HAND100 | Hard wired | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |
| RLY3-OSSD200 | — | |||
| RLY3-LOOP100 | Hard wired, DIP switch | 4 mA ... 6 mA | ≤ 15 mA | ≤ 120 mA |