Schneider LRD3656 technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSysTeSys Deca |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 70 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Network type | DCAC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7Vibrations: 4 gn conforming to IEC 60068-2-6 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACDNV-GLRMRSEU-RO MRLROS (Lloyds register of shipping)ATEX INERISUKCA |
| Permissible current | 0.95 A at 380 V AC-15 for signalling circuit0.06 A at 440 V DC-13 for signalling circuit |
| Depth | 123 mm |
| Width | 55 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 48…65 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 6 N.m - on lugs-ring terminals M6 |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.375 kg |
Overview
Technical Specifications of Schneider Electric Industrial Motor Protection Relay LRD3656: Call us for Schneider Electric Industrial Motor Protection Relay LRD3656 at the best rates. Technical Attributes of LRD3656 are device short name LRD, from the TeSysTeSys Deca range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 70 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The control type consists of a Red push-button: stopBlue push-button: reset.
Datasheet
Schneider datasheetschneider-electric-lrd3656.pdfOther models in this series
Compare LRD3656 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD3656 (this model) | TeSysTeSys Deca | 48…65 A | 6 kV | DCAC |
| LRD226 | TeSysTeSys Deca | 16…24 A | 6 kV | DCAC |
| LRD326 | TeSysTeSys Deca | 23…32 A | 6 kV | DCAC |
| LRD32L | TeSysTeSys Deca | 23…32 A | 6 kV | DCAC |
| LRD33696 | TeSys | 110…140 A | 6 kV | ACDC |
| LRD340L | TeSysTeSys Deca | 30…40 A | 6 kV | ACDC |
| LRD3321 | TeSys | 12…18 A | 6 kV | DC |
| LRD3314 | TeSys | — | 6 kV | DC |
| LRD3312 | TeSys | 5.5…8 A | 6 kV | DC |