
Image for reference. Refer to the datasheet for exact dimensions.
LRD3321: Schneider Electric Relay With Reset Function
Schneider LRD3321, Electric Relay With Reset Function. Protect motors—get a quote from IndMALL today for reliable motor control with reset capability
- Brand
- Schneider
- Model number
- LRD3321
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LRD3321 technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 81 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Network type | DC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| [Ue] rated operational voltage | 1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACCEUKCA |
| Permissible current | 1.5 A at 240 V AC-15 for signalling circuit0.1 A at 250 V DC-13 for signalling circuit |
| Depth | 115 mm |
| Width | 70 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 2.2 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 12…18 A |
| Relay application | Motor protection |
| Net weight | 0.51 kg |
Overview
Technical Specifications of Schneider Electric Relay With Reset Function LRD3321: Mail Us for your needs in Schneider Electric Relay With Reset Function LRD3321 with budget-friendly prices. The Main Technical Parameters of LRD3321 include device short name LRD, from the TeSys range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 81 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The control type consists of a Red push-button: stopBlue push-button: reset.
Datasheet
Schneider datasheetschneider-electric-lrd3321.pdfOther models in this series
Compare LRD3321 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD3321 (this model) | TeSys | 12…18 A | 6 kV | DC |
| LRD226 | TeSysTeSys Deca | 16…24 A | 6 kV | DCAC |
| LRD326 | TeSysTeSys Deca | 23…32 A | 6 kV | DCAC |
| LRD32L | TeSysTeSys Deca | 23…32 A | 6 kV | DCAC |
| LRD33696 | TeSys | 110…140 A | 6 kV | ACDC |
| LRD340L | TeSysTeSys Deca | 30…40 A | 6 kV | ACDC |
| LRD3656 | TeSysTeSys Deca | 48…65 A | 6 kV | DCAC |
| LRD3314 | TeSys | — | 6 kV | DC |
| LRD3312 | TeSys | 5.5…8 A | 6 kV | DC |