Image for reference. Refer to the datasheet for exact dimensions.
LRD07L: Schneider Overload Relay For Motor Safety
Schneider LRD07L, Overload Relay For Motor Safety. Protect motors—request a quote from IndMALL today for industrial-grade motor safety solutions.
- Brand
- Schneider
- Model number
- LRD07L
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LRD07L technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSysTeSys Deca |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 66 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Network type | ACDC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7Vibrations: 3 GN conforming to IEC 60068-2-6 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSAEACABSATEX INERISUKCA |
| Permissible current | 3 A at 120 V AC-15 for signalling circuit0.22 A at 125 V DC-13 for signalling circuit |
| Depth | 76 mm |
| Width | 45 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 1.6…2.5 A |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 1.7 N.m - on screw clamp terminals |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.144 kg |
Overview
Technical Specifications of Schneider Overload Relay For Motor Safety LRD07L: Talk to Our Engineer for Schneider Overload Relay For Motor Safety LRD07L with exclusive offers. Core System Specifications of LRD07L are device short name LRD, from the TeSysTeSys Deca range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 66 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. The control type consists of a Red push-button: stopBlue push-button: reset.
Datasheet
Schneider datasheetschneider-electric-lrd07l.pdfOther models in this series
Compare LRD07L with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD07L (this model) | TeSysTeSys Deca | 1.6…2.5 A | 6 kV | ACDC |
| LR9D5567 | TeSys | 60…100 A | 6 kV conforming to IEC 60947-1 | AC |
| LRD05L | TeSysTeSys Deca | 0.63…1 A | 6 kV | DCAC |
| LRD06L6 | TeSys | 1…1.6 A | 6 kV | ACDC |
| LRD076 | TeSysTeSys Deca | 1.6…2.5 A | 6 kV | DCAC |
| LRD07L6 | TeSysTeSys Deca | 1.6…2.5 A | 6 kV | ACDC |
| LRD08L | TeSysTeSys Deca | 2.5…4 A | 6 kV | ACDC |
| LRD143 | TeSysTeSys Deca | 7…10 A | 6 kV | ACDC |
| LRD14L | TeSysTeSys Deca | 7…10 A | 6 kV | ACDC |