Image for reference. Refer to the datasheet for exact dimensions.
LC1K0610F72: Schneider TeSys K 6A Contactor 110VAC Coil
Schneider LC1K0610F72, 6A TeSys K Contactor 110VAC Coil. Ensure system safety—ask IndMALL for pricing today for trusted contactor solutions.
- Brand
- Schneider
- Model number
- LC1K0610F72
- Series
- Schneider Contactors TeSys K Miniature Contactors
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LC1K0610F72 technical specifications
| Range | TeSys |
|---|---|
| Product or Component Type | Contactor |
| Device short name | LC1K |
| Contactor application | Motor control |
| Utilisation category | AC-3AC-3eAC-4 |
| Poles description | 3P |
| Power pole contact composition | 3 NO |
| [Ue] rated operational voltage | Power circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz |
| [Ie] rated operational current | 6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3 for power circuit6 A (at <140 °F (60 °C)) at <= 440 V AC AC-3e for power circuit |
| Control circuit type [Uc] | AC 50/60 Hz |
| Control circuit voltage | 110 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Overvoltage category | III |
| [Ith] conventional free air thermal current | 20 A (at 140 °F (60 °C)) for power circuit10 A (at 122 °F (50 °C)) for signalling circuit |
| Irms rated making capacity | 110 A AC for power circuit conforming to IEC 60947110 A AC for signalling circuit conforming to IEC 60947 |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
| [Icw] rated short-time withstand current | 90 A 122 °F (50 °C) - 1 s for power circuit85 A 122 °F (50 °C) - 5 s for power circuit80 A 122 °F (50 °C) - 10 s for power circuit60 A 122 °F (50 °C) - 30 s for power circuit45 A 122 °F (50 °C) - 1 min for power circuit40 A 122 °F (50 °C) - 3 min for power circuit20 A 122 °F (50 °C) - >= 15 min for power circuit80 A - 1 s for signalling circuit90 A - 500 ms for signalling circuit110 A - 100 ms for signalling circuit |
| Associated fuse rating | 25 A gG at <= 440 V for power circuit25 A aM for power circuit10 A gG for signalling circuit conforming to IEC 6094710 A gG for signalling circuit conforming to VDE 0660 |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| [Ui] rated insulation voltage | Power circuit 600 V UL 508Power circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-5-1Signalling circuit 600 V UL 508Power circuit 600 V CSA C22.2 No 14Signalling circuit 600 V CSA C22.2 No 14 |
| Inrush power in W | - |
| Hold-in power consumption in W | - |
| Heat dissipation | 1.3 W |
| Control circuit voltage limits | Operational: 0.8...1.15 Uc (at <122 °F (50 °C))Drop-out: >= 0.20 Uc (at <122 °F (50 °C)) |
| Connections - terminals | screw clamp terminals 1 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 1 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 1 0.0005…0.004 in² (0.34…2.5 mm²)flexible with cable end screw clamp terminals 2 0.002…0.006 in² (1.5…4 mm²)solid screw clamp terminals 2 0.001…0.006 in² (0.75…4 mm²)flexible without cable end screw clamp terminals 2 0.0005…0.002 in² (0.34…1.5 mm²)flexible with cable end |
| Maximum operating rate | 3600 cyc/h |
| Mounting Support | PlateRail |
| Operating time | 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing |
| Height | 2.3 in (58 mm) |
| Width | 1.8 in (45 mm) |
| Depth | 2.2 in (57 mm) |
| Net Weight | 0.40 lb(US) (0.18 kg) |
| IP degree of protection | IP2X VDE 0106 |
| Ambient air temperature for operation | - |
| Ambient Air Temperature for Storage | -58…176 °F (-50…80 °C) |
| Operating altitude | 6561.68 ft (2000 m) without derating |
Overview
Technical Specifications of Schneider TeSys K 6A Contactor 110VAC Coil LC1K0610F72: Talk to Our Engineer for Schneider TeSys K 6A Contactor 110VAC Coil LC1K0610F72 with exclusive offers. Core System Specifications of LC1K0610F72 are Contactor Product or Component Type 3 NO power pole contact composition. This contactor operates with a rated operational voltage of up to Power circuit <= 690 V AC <= 400 HzSignalling circuit <= 690 V AC <= 400 Hz, ensuring flexibility in various industrial applications. The compact design includes a height of 2.3 in (58 mm), a width of 1.8 in (45 mm), and a depth of 2.2 in (57 mm).
Datasheet
Schneider datasheetschneider-electric-lc1k0610f72.pdfOther models in this series
Compare LC1K0610F72 with similar models in the same series. See all 172 models on the Schneider Contactors TeSys K Miniature Contactors page.
| Model | Hold-in power consumption in W | Power pole contact composition | Contactor application | Depth |
|---|---|---|---|---|
| LC1K0610F72 (this model) | - | 3 NO | Motor control | 2.2 in (57 mm) |
| LC1K09008G7 | - | 2 NO + 2 NC | Resistive load | 57 mm |
| LP1K1210BD3 | 3 W at 20 °C | 3 NO | Motor controlResistive load | 57 mm |
| LC1K0601G7 | - | 3 NO | Motor control | 2.2 in (57 mm) |
| LC1K1210E7 | - | 3 NO | Resistive loadMotor control | 57 mm |
| LC1K12004B7 | - | 4 NO | Resistive load | 2.2 in (57 mm) |
| LC1K0610P7 | - | 3 NO | Motor control | 57 mm |
| LC1K1201F7 | - | 3 NO | Resistive loadMotor control | 57 mm |
| LC1K0610U7 | - | 3 NO | Motor control | 57 mm |