
Image for reference. Refer to the datasheet for exact dimensions.
LC1K1201F7: Schneider 110V AC Coil For Contactors
Schneider LC1K1201F7, 110V AC Coil for Contactors. Boost system control—ask IndMALL for pricing today and optimize your system’s efficiency.
- Brand
- Schneider
- Model number
- LC1K1201F7
- Series
- Schneider Contactors TeSys K Contactors
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LC1K1201F7 technical specifications
| Connections - terminals | Screw clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end |
|---|---|
| [Uc] control circuit voltage | 110 V AC 50/60 Hz |
| Minimum switching voltage | 17 V for signalling circuit |
| contactor application | Resistive loadMotor control |
| Width | 45 mm |
| Control circuit type | AC at 50/60 Hz |
| Average impedance | 3 mOhm - Ith 20 A 50 Hz for power circuit |
| Depth | 57 mm |
| [Ie] rated operational current | 12 A (at <60 °C) at <= 440 V AC AC-3 for power circuit12 A (at <60 °C) at <= 440 V AC AC-3e for power circuit20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
| Auxiliary contacts type | type instantaneous 1 NC |
| poles description | 3P |
| Auxiliary contact composition | 1 NC |
| IP degree of protection | - |
| [Ui] rated insulation voltage | - |
| Operating altitude | 2000 m without derating |
| Ambient air temperature for operation | - |
| Power pole contact composition | 3 NO |
| Hold-in power consumption in W | - |
| Ambient air temperature for storage | - |
| Utilisation category | AC-3AC-3eAC-1AC-4 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Heat dissipation | 1.3 W |
| Hold-in power consumption in VA | 4.5 VA (at 20 °C) |
| Net weight | - |
| Minimum switching current | 5 mA for signalling circuit |
| Mounting support | - |
| Operating time | 10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing |
| Rated breaking capacity | 110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
| Product or component type | Contactor |
| Tightening torque | - |
| Maximum operating rate | 3600 cyc/h |
| Range | TeSys |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
| Height | 58 mm |
| Motor power kW | 3 kW at 220...230 V AC 50/60 Hz AC-35.5 kW at 380...415 V AC 50/60 Hz AC-35.5 kW at 440 V AC 50/60 Hz AC-34 kW at 690 V AC 50/60 Hz AC-33 kW at 220...230 V AC 50/60 Hz AC-3e5.5 kW at 380...415 V AC 50/60 Hz AC-3e5.5 kW at 440 V AC 50/60 Hz AC-3e4 kW at 690 V AC 50/60 Hz AC-3e3 kW at 220...230 V AC 50/60 Hz AC-45.5 kW at 380...415 V AC 50/60 Hz AC-45.5 kW at 440 V AC 50/60 Hz AC-44 kW at 690 V AC 50/60 Hz AC-4 |
| Inrush power in W | - |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Electrical durability | 1.3 Mcycles 12 A AC-3 at Ue <= 440 V1.3 Mcycles 12 A AC-3e at Ue <= 440 V0.3 Mcycles 20 A AC-1 at Ue <= 690 V0.02 Mcycles 72 A AC-4 at Ue <= 440 V |
| Device short name | LC1K |
Overview
Technical Specifications of Schneider 110V AC Coil For Contactors LC1K1201F7: Give Us a Call for Schneider 110V AC Coil For Contactors LC1K1201F7 at the lowest pricing. In-depth Technical Analysis of LC1K1201F7 feature control circuit voltage [Uc] operates at 110 V AC 50/60 Hz, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. The control circuit type is AC at 50/60 Hz, and the auxiliary contacts are type instantaneous 1 NC configuration, providing reliable switching. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient.
Datasheet
Schneider datasheetschneider-electric-lc1k1201f7.pdfOther models in this series
Compare LC1K1201F7 with similar models in the same series. See all 120 models on the Schneider Contactors TeSys K Contactors page.
| Model | [Uc] control circuit voltage | Minimum switching voltage | Hold-in power consumption in VA | Hold-in power consumption in W |
|---|---|---|---|---|
| LC1K1201F7 (this model) | 110 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LP4K1210EW3 | 48 V DC | 17 V for signalling circuit | - | 1.8 W at 20 °C |
| LP1K0910MD | 220 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LC1K1601F7 | 110 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LC1K0910P7 | 230 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LC1K09008G7 | 120 V AC 50/60 Hz | - | 4.5 VA (at 20 °C) | - |
| LC1K09105E7 | 48 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LC1K0610P7 | 230 V AC 50/60 Hz | 17 V for signalling circuit | 4.5 VA (at 20 °C) | - |
| LP1K1210BD3 | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |