Image for reference. Refer to the datasheet for exact dimensions.
ATS130N2D80LT: Schneider 80A Altivar Soft Starter
Schneider ATS130N2D80LT, 80A Altivar Soft Starter. Efficient and stable—request your IndMALL quote today for reliable soft starter solutions.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATS130N2D80LT technical specifications
| Power supply frequency | 50...60 Hz +/- 5 Hz |
|---|---|
| Operating cycles/hour | 25 cyc/h |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Height | 197 mm |
| Relay output number | 1 |
| Display type | 1 LED (green) for control power energized1 LED (yellow and red) for motor operation phases, errors |
| Pollution degree | Level 2 |
| Minimum motor current | 20 % Ie |
| Protection type | Phase failure: mainsThermal protection: starterBypass error: starterControl voltage Us: starter |
| Package 1 Length | 28.000 cm |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Environmental class (during operation) | Without salt mist: 3C3 conforming to IEC 60721-3-33S3 conforming to IEC 60721-3-3 |
| Suitable for mounting onto standard rails | TRUE |
| Overload current profile | 300 % Ie for 5 s |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Function available | Deceleration voltage rampBoost |
| Minimum switching current | 2.5 mA at 24 V DC for relay outputs |
| Operating altitude | 0...1000 m without derating1000...4000 m 1 % per 100 m |
| Package 1 Weight | 2.560 kg |
| Motor power hp | 25 hp at 200 V normal duty25 hp at 208 V normal duty30 hp at 230 V normal duty60 hp at 460 V normal duty60 hp at 480 V normal duty |
| IP degree of protection | IP20 |
| Ambient air transport temperature | -40…70 °C |
| Product or component type | Soft starter |
| Utilisation category | AC-53A |
| Ue power supply voltage | 200...480 V - 15...10 % |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cyclesOn resistive load for relay outputs : 1 A 30 V DC 400000 cyclesOn inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cyclesOn inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Depth | 180 mm |
| Operating position | Vertical +/- 30 degree |
| [Ui] rated insulation voltage | 480 V |
| Network number of phases | 3 phases |
| Input compatibility | Discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Device connection | In line |
| Width | 81 mm |
| Torque control | FALSE |
| Ambient air temperature for storage | -25…70 °C |
| Control power | 21.6 W starting and stopping3 W steady state |
| Range of product | Altivar Soft Starter ATS130 |
| [Uc] control circuit voltage | 24 V DC |
| Relative humidity | 5…95 % non condensing without dripping water conforming to IEC 60068-2-3 |
| Power loss per device current dependent | 16 W |
| Net weight | 2.3 kg |
| [Ie] rated operational current | 80 A in line (at <40 °C) |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Ambient air temperature for operation | -10…40 °C (without derating)40…60 °C (with current derating of 2 % per °C) |
| Motor power kW | 22 kW at 230 V normal duty45 kW at 400 V normal duty45 kW at 440 V normal duty |
| Power loss static current independent | 3 W |
| Power loss during starting | 512 W 300 % Ie |
| Relay output type | Relay outputs R1A, R1C NO |
| Number of Units in Package 1 | 1 |
Overview
The ATS130N2D80LT is a high-performance soft starter from Schneider Electric , part of the trusted Altivar ATS130 Soft Starter range. Its rugged build allows vertical installation ±30°, with a temperature range of -10°C to 60°C (with derating above 40°C). The Uc control voltage is 24 V DC , and it includes relay output R1A/R1C NO . With dimensions of 197 mm (H) × 81 mm (W) × 180 mm (D) and a net weight of 2.3 kg , this unit is DIN-rail compatible and IP20 rated. Power losses are 512 W during startup and 3 W static. This helps prolong equipment life and reduces energy surges.
Datasheet
Schneider datasheetschneider-electric-ats130n2d80lt.pdfOther models in this series
Compare ATS130N2D80LT with similar models in the same series. See all 27 models on the Altivar Soft Starter page.
| Model | Range of Product | Relay output number | Power supply frequency | Ue power supply voltage |
|---|---|---|---|---|
| ATS130N2D80LT (this model) | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS480C79Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480M10Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480M12Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS130N2D38LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D45LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D65LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D73LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2C11LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |