
Image for reference. Refer to the datasheet for exact dimensions.
ATS130N2D45LT: Schneider Altivar Soft Starter ATS130
Schneider ATS130N2D45LT, Altivar Soft Starter ATS130 45A. Enhance system control—get your IndMALL quote today for reliable soft starter solutions.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATS130N2D45LT technical specifications
| Power supply frequency | 50...60 Hz +/- 5 Hz |
|---|---|
| Operating cycles/hour | 35 cyc/h |
| Maximum deflection under vibratory load (during transport) | 3 mm at 2-9 Hz |
| Maximum acceleration under vibratory load (during storage) | 10 m/s² at 9...200 Hz |
| Height | 166 mm |
| Relay output number | 1 |
| Display type | 1 LED (green) for control power energized1 LED (yellow and red) for motor operation phases, errors |
| Pollution degree | Level 2 |
| Minimum motor current | 20 % Ie |
| Protection type | Phase failure: mainsThermal protection: starterBypass error: starterControl voltage Us: starter |
| Package 1 Length | 28.000 cm |
| Maximum acceleration under vibrational stress (during operation) | 10 m/s² at 9...200 Hz |
| Environmental class (during operation) | Without salt mist: 3C3 conforming to IEC 60721-3-33S3 conforming to IEC 60721-3-3 |
| Suitable for mounting onto standard rails | TRUE |
| Overload current profile | 300 % Ie for 5 s |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Function available | Deceleration voltage rampBoost |
| Minimum switching current | 2.5 mA at 24 V DC for relay outputs |
| Operating altitude | 0...1000 m without derating1000...4000 m 1 % per 100 m |
| Package 1 Weight | 1.515 kg |
| Motor power hp | 10 hp at 200 V normal duty10 hp at 208 V normal duty15 hp at 230 V normal duty30 hp at 460 V normal duty30 hp at 480 V normal duty |
| IP degree of protection | IP20 |
| Ambient air transport temperature | -40…70 °C |
| Product or component type | Soft starter |
| Utilisation category | AC-53A |
| Ue power supply voltage | 200...480 V - 15...10 % |
| Maximum switching current | On resistive load for relay outputs : 1 A 250 V AC 400000 cyclesOn resistive load for relay outputs : 1 A 30 V DC 400000 cyclesOn inductive load for relay outputs : 1 A 250 V AC cos phi = 0.4 100000 cyclesOn inductive load for relay outputs : 1 A 30 V DC cos phi = 0.4 100000 cycles |
| Depth | 165 mm |
| Operating position | Vertical +/- 30 degree |
| [Ui] rated insulation voltage | 480 V |
| Network number of phases | 3 phases |
| Input compatibility | Discrete input level 1 PLC conforming to EN/IEC 61131-2 |
| Device connection | In line |
| Width | 55 mm |
| Torque control | FALSE |
| Ambient air temperature for storage | -25…70 °C |
| Control power | 21.6 W starting and stopping3 W steady state |
| Range of product | Altivar Soft Starter ATS130 |
| [Uc] control circuit voltage | 24 V DC |
| Relative humidity | 5…95 % non condensing without dripping water conforming to IEC 60068-2-3 |
| Power loss per device current dependent | 9 W |
| Net weight | 1.3 kg |
| [Ie] rated operational current | 45 A in line (at <40 °C) |
| Maximum deflection under vibratory load (during storage) | 3 mm at 2-9 Hz |
| Ambient air temperature for operation | -10…40 °C (without derating)40…60 °C (with current derating 1.5 % per °C) |
| Motor power kW | 11 kW at 230 V normal duty22 kW at 400 V normal duty22 kW at 440 V normal duty |
| Power loss static current independent | 3 W |
| Power loss during starting | 264 W 300 % Ie |
| Relay output type | Relay outputs R1A, R1C NO |
| Number of Units in Package 1 | 1 |
Overview
The ATS130N2D45LT is a reliable soft starter from Schneider Electric , part of the high-performance Schneider Altivar Soft Starter ATS130 series. It supports 35 operating cycles/hour and delivers a rated current of 45 A in line operation at temperatures below 40°C. It includes 1 relay output (R1A, R1C NO) and supports a minimum switching current of 2.5 mA at 24 V DC . Environmental resilience includes vibration resistance, pollution degree 2 compliance, and safe operation between -10°C and 60°C (with derating above 40°C). The Schneider Altivar Soft Starter ATS130 model ATS130N2D45LT is widely used in HVAC systems, water pumps, blowers, packaging lines, and material handling systems.
Datasheet
Schneider datasheetschneider-electric-ats130n2d45lt.pdfOther models in this series
Compare ATS130N2D45LT with similar models in the same series. See all 27 models on the Altivar Soft Starter page.
| Model | Range of Product | Relay output number | Power supply frequency | Ue power supply voltage |
|---|---|---|---|---|
| ATS130N2D45LT (this model) | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS480C79Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480M10Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS480M12Y | Altivar Soft Starter ATS480 | 3 | 50...60 Hz - 20...20 % | 208...690 V - 15...10 % |
| ATS130N2D38LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D65LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D73LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2D80LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |
| ATS130N2C11LT | Altivar Soft Starter ATS130 | 1 | 50...60 Hz +/- 5 Hz | 200...480 V - 15...10 % |