
Image for reference. Refer to the datasheet for exact dimensions.
Omron H3CR-H8L AC/DC24 M Solid-state Timer
Omron H3CR-H8L AC/DC24 M Timer with 85 to 110% of the power supply voltage, 4 time ranges, Power OFF-delay, 8-pin round socket.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron H3CR-H8L AC/DC24 M technical specifications
| Rated power supply voltage | 24 VAC 50/60 Hz 24 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier) |
|---|---|
| Allowable voltage variable range | 85 to 110% of the power supply voltage |
| Number of time ranges | 4 |
| Operation mode | Power OFF-delay |
| Control output (Type) | Time-limit: DPDT |
| Control output (Contact output) | Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value) |
| Operating resetting | Instantaneous operation/Time-limit reset |
| Connection method | 8-pin round socket |
| Power consumption | Approx. 0.17 VA (at 24 VAC) Approx. 0.15 W (at 24 VAC)/Approx. 1 W (at 24 VDC) |
| Ambient temperature range | Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
| Accuracy of operating time | ±0.2% FS max |
| Setting error | ±5% FS ±50 ms max. |
| Influence of voltage | ±0.2% FS max |
| Influence of temperature | ±1% FS max |
| Insulation resistance | 100 MΩ min. (at 500 VDC) |
| Dielectric strength | Between current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between power terminals: 1 kV Between current carrying terminals and exposed non-current carrying metal parts: 1.5 kV |
| Noise immunity | ±1.5 kV (between power terminals) and ±600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
| Static immunity | Mulfunction: 8 kV, Destruction: 15 kV |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 980 m/s2, 3 times each in 6 directions Malfunction: 98 m/s2, 3 times each in 6 directions |
| Degree of protection | IP40 (panel surface) |
| Ambient temperature range | Operating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
| Ambient humidity range | Operating: 35 to 85% |
| Life expectancy (relay output) | Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1200 operations/h) Mechanical: 10 million operations min. (under no load at 1,200 operations/h) |
| Operation start voltage | 30% max. of rated supply voltage |
| Weight | Approx. 120 g |
Overview
The Omron H3CR-H8L AC/DC24 M Timer is built for dependable timing control with an allowable voltage variable range of 85 to 110% of the power supply voltage and an operation start voltage of 30% max. of rated supply voltage. It supporting 4 time ranges for dependable performance. Designed for Power OFF-delay operation, it provides a reliable DPDT time-limit control output through an 8-pin round socket connection. Manufactured by Omron , listed under Omron Timers , and part of the Omron H3CR Series .
Datasheet
Omron datasheeth3cr-datasheet.pdfOther models in this series
Compare H3CR-H8L AC/DC24 M with similar models in the same series. See all 35 models on the H3CR Series page.
| Model | Number of time ranges | Degree of protection |
|---|---|---|
| H3CR-H8L AC/DC24 M (this model) | 4 | IP40 (panel surface) |
| H3CR-G8EL AC200-240 | Type: Analog · Installation type: Socket · Size: 1/16 DIN (48 x 48 mm) | |
| H3CR-G8L AC100-120 | 4 | IP40 (panel surface) |
| H3CR-G8L AC200-240 | 4 | IP40 (panel surface) |
| H3CR-G8L-30 AC200-240 | 4 | IP40 (panel surface) |
| H3CR-H8L AC100-120 M | 4 | IP40 (panel surface) |
| H3CR-H8L AC100-120 S | 4 | IP40 (panel surface) |
| H3CR-H8L AC200-240 M | 4 | IP40 (panel surface) |
| H3CR-H8L AC200-240 S | 4 | IP40 (panel surface) |