Omron H3CR-G8L AC100-120 Timer with 85 to 110% of the power supply voltage, 4 time ranges, Star-delta, 8-pin round socket.

Brand
Omron
Model number
H3CR-G8L AC100-120
Series
H3CR Series
Product type
Timers

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Omron H3CR-G8L AC100-120 technical specifications

Rated power supply voltage100/110/120 VAC 50/60 Hz
Allowable voltage variable range85 to 110% of the power supply voltage
Number of time ranges4
Operation modeStar-delta
Control output (Type)Time-limit: SPST-NO (Start operation circuit) SPST-NO (Delta operation circuit) ,Instantaneous: SPST-NO
Control output (Contact output)Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
Operating resettingTime-limit operation/Self-reset
Connection method8-pin round socket
Power consumptionApprox. 6 VA (at 120 VAC) Approx. 2.6 W (at 120 VAC)
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Accuracy of operating time±0.2% FS max
Setting error±5% FS ±50 ms max.
Influence of voltage±0.2% FS max.
Influence of temperature±1% FS max
Insulation resistance100 MΩ min. (at 500 VDC)
Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
Impulse withstand voltageBetween power terminals: 5 kV Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
Noise immunity±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Static immunityMulfunction: 8 kV, Destruction: 15 kV
Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
Shock resistanceDestruction: 980 m/s2, 3 times each in 6 directions Malfunction: 294 m/s2, 3 times each in 6 directions
Degree of protectionIP40 (panel surface)
Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing)
Ambient humidity rangeOperating: 35 to 85%
Life expectancy (relay output)Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
Operation start voltage10% max. of rated supply voltage
WeightApprox. 110 g
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

The Omron H3CR-G8L AC100-120 Timer is built for dependable timing control with an allowable voltage variable range of 85 to 110% of the power supply voltage and an operation start voltage of 10% max. of rated supply voltage. It supporting 4 time ranges for dependable performance. Designed for Star-delta operation, and an 8-pin round socket connection. Manufactured by Omron , listed under Omron Timers , and part of the Omron H3CR Series .

Datasheet

Omron datasheeth3cr-datasheet.pdf

Other models in this series

Compare H3CR-G8L AC100-120 with similar models in the same series. See all 35 models on the H3CR Series page.

H3CR-G8L AC100-120 compared with other models in the series
ModelNumber of time rangesDegree of protection
H3CR-G8L AC100-120 (this model)4IP40 (panel surface)
H3CR-F8 AC24-48/DC12-4818IP40 (panel surface)
H3CR-F8N AC100-240/DC100-12518IP40 (panel surface)
H3CR-F8N AC24-48/DC12-4818IP40 (panel surface)
H3CR-G8EL AC200-240Type: Analog · Installation type: Socket · Size: 1/16 DIN (48 x 48 mm)
H3CR-G8L AC200-2404IP40 (panel surface)
H3CR-G8L-30 AC200-2404IP40 (panel surface)
H3CR-H8L AC/DC24 M4IP40 (panel surface)
H3CR-H8L AC100-120 M4IP40 (panel surface)