Delta RTU-DNET DeviceNet Remote I/O Module
Delta RTU-DNET Programmable Logic Controller supports DeviceNet protocol, CAN communication, 256 I/O points, and 125k–500k bps networking.
- Brand
- Delta
- Model number
- RTU-DNET
- Series
- DVP-S Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta RTU-DNET technical specifications
| Supports | DeviceNet protocol |
|---|---|
| Connectable | 8 DVP-S series analog I/O modules, Connectable to 256 points of digital I/O modules |
| Storage /Operation Temperature | Storage: -25ºC ~70ºC (temperature)Operation: 0ºC ~55ºC (temperature) |
| Storage /Operation humidity | 5%~95% (humidity)5%~95% (humidity); pollution degree 2 |
| Vibration/shock immunity | Standard: IEC 61131-2、IEC 68-2-6 (TEST Fc)/IEC 61131-2 & IEC 68-2-27(TEST Ea) |
| Transmission method | CAN |
| Connector | Removable, 5.08mm |
| Serial baudrate | 125k, 250k, 500k bps |
| Message type | Explicit, I/O polled |
| Network voltage | 24 VDC (11 to 25 VDC) |
| Communication cable | Shielded twisted pair cable |
| Interference immunity | ESD (IEC 61131-2, IEC 61000-4-2): 8 kV Air DischargeEFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2 kV, Digital I/O: 1 kVAnalog & Communication I/O: 1 kVDamped-Oscillatory Wave: Power Line: 1 kV, Digital I/O: 1 kVRS (IEC 61131-2, IEC 61000-4-3): 26 MHz ~ 1 GHz, 10 V/m |
Overview
Delta RTU-DNET Programmable Logic Controller (PLC) is an industrial-grade DeviceNet Remote I/O Module designed for scalable expansion of DVP-based automation systems. It supports the DeviceNet protocol , connects up to 8 DVP-S series analog I/O modules and 256 digital I/O points , and operates at 125k, 250k, and 500k bps using CAN-based communication. In practical automation systems, the RTU-DNET is used to connect distributed analog and digital I/O near field devices such as sensors, actuators, and control panels. By supporting up to 256 I/O points, it reduces wiring complexity and improves system scalability in packaging lines, conveyors, assembly stations, and process automation setups where decentralized control is required.
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare RTU-DNET with similar models in the same series. See all 205 models on the DVP-S Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| RTU-DNET (this model) | Transmission method: CAN · Connector: Removable, 5.08mm · Message type: Explicit, I/O polled | |||
| DVP20SX211T | Analog (2), Relay (6) | 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | 16k Steps |
| DVP20PM00D | — | 2A/ 250VAC | 60 VA | 64K Steps |
| DVP20PM00M | — | 2A/ 250VAC | 60 VA | 64K Steps |
| DVP10PM00M | 16 | 2A/ 250VAC | 60VA | 64k steps |
| DVP20PM00DT | 8 | 2A/ 250VAC | 60 VA | 64k steps |
| DVP10MC11T | 4 Outputs | 3 A/30 VDC, Polyswitch | 8 W Max | Ladder 16k steps / Motion 1Mbyte |
| RTU-485 | Transmission method: RS-485 · Connector: 3-pin, removable · Data type: Modbus ASCII/RTU | |||
| RTU-EN01 | — | — | 2 W | — |