Image for reference. Refer to the datasheet for exact dimensions.
Delta DVP20SX211T - DVP SX2 PLC Controller
Delta DVP20SX211T Programmable Logic Controller from the DVP-SX2 Series with mixed analog and digital I/O, transistor outputs, and 24VDC operation.
- Brand
- Delta
- Model number
- DVP20SX211T
- Series
- DVP-SX2 Series
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DVP20SX211T technical specifications
| Type | CPU |
|---|---|
| Output Type | Transistor |
| Number of Inputs and Type | 12 – Digital (8), Analog (4) |
| Number of Outputs and Type | Analog (2), Relay (6) |
| Power Supply Voltage | 24VDC (-15%~20%) |
| Fuse Capacity | 2A/ 250VAC; SV: 2.5A/ 30VDC |
| Data register | 10k words |
| Program capacity | 16k Steps |
| Spike Voltage Durability | 1500VAC (Primary-secondary); 1500VAC (Primary-PE); 500VAC (Secondary-PE) |
| Insulation Impedance | >5 MΩ (all I/O point-to-ground: 500VDC) |
| Noise Immunity | ESD: 8 kV Air DischargeEFT: Power Line, 2 kVDigital I/O: 1 kVAnalog & Communication I/O |
| Input Signal Voltage | 24VDC ±10% (5 mA) |
| Earth | The diameter of the grounding wire shall not be shorter than that of the power supply cable.(When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) |
| Power consumption | 4W |
| Max. Input Frequency | 100KHz |
| Storage /Operation Temperature | Storage: -25ºC ~70ºC (temperature)Operation: 0ºC ~55ºC (temperature) |
| Storage /Operation humidity | 5%~95% (humidity)5%~95% (humidity); pollution degree 2 |
| Response Time | OFF→ON: 3.5μsON→OFF: 20μs |
Overview
Delta DVP20SX211T Programmable Logic Controller (PLC) is a mixed-signal CPU designed to handle both analog and digital control within compact automation systems. As part of the DVP SX2 series, it integrates digital inputs, analog inputs, analog outputs, and transistor outputs into one CPU, allowing efficient signal handling without additional expansion modules. Its mixed I/O capability enables consistent coordination between analog measurement and digital switching, improving control accuracy and system response. From a system perspective, the DVP20SX211T PLC fits structured control applications that demand stable performance over continuous operation. This clear relationship between model, control type, and application makes it suitable for automation systems that require balanced analog and digital functionality.
Datasheet
Delta datasheetdvp-series.pdfOther models in this series
Compare DVP20SX211T with similar models in the same series. See all 205 models on the DVP-SX2 Series page.
| Model | Number of Outputs and Type | Fuse Capacity | Power consumption | Program capacity |
|---|---|---|---|---|
| DVP20SX211T (this model) | Analog (2), Relay (6) | 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | 16k Steps |
| DVP28SV11S2 | 12 – Transistor | 2A/ 250VAC; SV: 2.5A/ 30VDC | — | 30k Steps |
| DVP28SV11T2 | 12 – Transistor | 2.5A/30VDC, Polyswitch | 6W | 30k Steps |
| DVP20SX211R | Analog (2), Relay (6) | 2A/ 250VAC; SV: 2.5A/ 30VDC | — | 16k Steps |
| DVP20SX211S | Analog (2), Solid State (6) | 2A/ 250VAC; SV: 2.5A/ 30VDC | 4W | 16k Steps |
| DVP20PM00D | — | 2A/ 250VAC | 60 VA | 64K Steps |
| DVP20PM00M | — | 2A/ 250VAC | 60 VA | 64K Steps |
| DVP10PM00M | 16 | 2A/ 250VAC | 60VA | 64k steps |
| DVP20PM00DT | 8 | 2A/ 250VAC | 60 VA | 64k steps |