IndMALL 2.0 preview — for review only, not indexed by search engines. Links reflect the live IndMALL site; WhatsApp buttons open the real IndMALL enquiry number.

Industrial automation products & suppliers across India

Telemecanique XCSB802: Safety Switches

Image for reference. Refer to the datasheet for exact dimensions.

Telemecanique XCSB802: Safety Switches

The Telemecanique XCSB802 is a safety switch (XCSB): 3 NC, IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1.

Brand
Telemecanique
Model number
XCSB802
Series
Telemecanique Safety Switches

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Telemecanique XCSB802 key specifications

TypeSafety switch
Model rangeXCSB
ShapeIndustrial
Head typeKey operated turret head
Contacts3 NC
Contact operationSlow-break, simultaneous
Positive openingWith NC contact
ConnectionTerminal, clamping capacity: 1 x 0.5...2 x 1.5 mm² with or without cable end
Cable entry1 entry tapped for M20 x 1.5
Thermal current (Ithe)10 A
Housing materialZamak
Head materialZamak
Safety levelUp to category 4 (ISO 13849-1), PL e (ISO 13849-1), SIL 3 (IEC 61508) with a suitable safety monitoring module
Degree of protectionIP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1
Operating temperature-25 to 70 °C
Source: Telemecanique product data, checked 27 Nov 2026.

Datasheet

Telemecanique datasheettelemecaniquesensors-xcsb802.pdf

Other models in this series

Compare XCSB802 with similar models in the same series. See all 44 models on the Telemecanique Safety Switches page.

XCSB802 compared with other models in the series
ModelContact operationContactsCable entry
XCSB802 (this model)Slow-break, simultaneous3 NC1 entry tapped for M20 x 1.5
XCSB713Slow-break, break before make2 NC + 1 NO1 entry tapped for 1/2" NPT
XCSB713FW1Slow-break, break before make2 NC + 1 NO1 entry tapped for 1/2" NPT
XCSB723Slow-break, break before make2 NC + 1 NO1 entry tapped for 1/2" NPT
XCSB801Slow-break, simultaneous3 NC1 entry tapped for Pg 13.5
XCSB803Slow-break, simultaneous3 NC1 entry tapped for 1/2" NPT
XCSC501Slow-break, break before make1 NC + 2 NO1 entry tapped for Pg 13.5
XCSC502Slow-break, break before make1 NC + 2 NO1 entry tapped for M20 x 1.5
XCSC503Slow-break, break before make1 NC + 2 NO1 entry tapped for 1/2" NPT

Telemecanique XCSB802: frequently asked questions

What contacts does the XCSB802 have?

3 NC, slow-break, simultaneous.

What safety level can the XCSB802 reach?

Up to category 4 (ISO 13849-1), PL e (ISO 13849-1), SIL 3 (IEC 61508) with a suitable safety monitoring module.

What current can the XCSB802 contacts carry?

Conventional enclosed thermal current (Ithe) 10 A.

What IP rating does the XCSB802 have?

IP67 conforming to EN/IEC 60529 and EN/IEC 60947-5-1.