Image for reference. Refer to the datasheet for exact dimensions.
Sick BCG05-L1KM01PP: Wire Draw Encoders
Call us for Sick Wire Draw Encoders BCG05-L1KM01PP at competitive rates. 19 V DC ... 33 V DC, 0 m ... 1.25 m, ≤ 80 mA.
- Brand
- Sick
- Model number
- BCG05-L1KM01PP
- Series
- Sick Wire Draw Encoder
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Sick BCG05-L1KM01PP technical specifications
| Measurement range | 0 m ... 1.25 m |
|---|---|
| Encoder | Absolute encoders |
| Resolution (wire draw + encoder) | 0.04 mm 1) 2) |
| Repeatability | ≤ 0.2 mm 3) |
| Linearity | ≤ ± 2 mm 3) |
| Hysteresis | ≤ 0.4 mm 3) |
| Communication interface | Analog / Voltage / 0...10 V |
| Connection type | Cable, radial, 1.5 m |
| Supply voltage | 19 V DC ... 33 V DC |
| Operating current | ≤ 80 mA |
| Weight | 0.18 kg |
| Measuring wire diameter | 0.45 mm |
| Weight (measuring wire) | 0.58 g/m |
| Housing material, wire draw mechanism | Plastic, Noryl |
| Spring return force | 1 N ... 1.4 N 1) |
| Length of wire pulled out per revolution | 150 mm |
| Actual wire draw length | 1.45 m |
| Wire acceleration | 10 m/s² |
| Operating speed | 6 m/s |
| Operating temperature range | –30 °C ... +70 °C |
Overview
The Sick BCG05-L1KM01PP encoder provides a 1.25 m measuring range with 0.04 mm resolution for accurate linear position feedback. It supports ≤ 0.2 mm repeatability , 0–10 V analog output , a 1.5 m radial cable , and operates on 19–33 V DC for stable measurement performance. This encoder is used in conveyors, packaging lines, assembly equipment, and machine-positioning applications where linear displacement must be measured reliably. The 0–10 V output ensures stable signal transmission, while the Noryl housing and smooth wire-draw mechanism support continuous operation in factory environments. It provides the accuracy, durability, and measurement consistency required for trusted operation in demanding automation setups.
Datasheet
Sick datasheetsick-bcg05-l1km01pp.pdfOther models in this series
Compare BCG05-L1KM01PP with similar models in the same series. See all 7 models on the Sick Wire Draw Encoder page.
| Model | Measurement range | Operating temperature range | Supply voltage | Resolution (wire draw + encoder) |
|---|---|---|---|---|
| BCG05-L1KM01PP (this model) | 0 m ... 1.25 m | –30 °C ... +70 °C | 19 V DC ... 33 V DC | 0.04 mm 1) 2) |
| BCG05-K1KM01PP | 0 m ... 1.25 m | –30 °C ... +70 °C | 19 V DC ... 33 V DC | 0.05 mm 1) 2) |
| BCG08-K1KM03PP | 0 m ... 3 m | –30 °C ... +70 °C | 19 V DC ... 33 V DC | 0.08 mm 1) 2) |
| BCG08-N1BM0399 | 0 m ... 3 m | –30 °C ... +70 °C | 10 V DC ... 30 V DC | 0.001 mm 1) 2) |
| BCG13-K1KM05PP | 0 m ... 5 m | –30 °C ... +70 °C | 19 V DC ... 33 V DC | 0.1 mm 1) 2) |
| PFG05-E1KM0160 | 0 m ... 1.25 m | –20 °C ... +70 °C | 7 V ... 30 V | 0.06 mm 1) 2) |
| BTF13-P1HM1025 | 0 m ... 10 m | –20 °C ... +70 °C | 10 V ... 32 V | 0.04 mm 1) 2) |