
Image for reference. Refer to the datasheet for exact dimensions.
LRD22: Motor Protection With Schneider Electric Relay
Schneider LRD22, Motor Protection With Schneider Electric Relay. Enhance control—ask IndMALL for pricing today and protect your motors.
- Brand
- Schneider
- Model number
- LRD22
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LRD22 technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSysTeSys Deca |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 66 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 10A conforming to IEC 60947-4-1 |
| Network type | DCAC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSACCCEACBVRINADNV-GLLROS (Lloyds register of shipping)ATEX INERISUKCA |
| Permissible current | 1.5 A at 240 V AC-15 for signalling circuit0.1 A at 250 V DC-13 for signalling circuit |
| Depth | 70 mm |
| Width | 45 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 16…24 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 2.5 N.m - on screw clamp terminals |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.124 kg |
Overview
Technical Specifications of Motor Protection With Schneider Electric Relay LRD22: IndMALL Automation Dealing offers Motor Protection With Schneider Electric Relay LRD22 at unbeatable prices. The Main Technical Parameters of LRD22 are device short name LRD, from the TeSysTeSys Deca range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 66 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. Choose us for unparalleled pricing and support over other Dealers & Distributors.
Datasheet
Schneider datasheetschneider-electric-lrd22.pdfOther models in this series
Compare LRD22 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD22 (this model) | TeSysTeSys Deca | 16…24 A | 6 kV | DCAC |
| LRD07 | TeSysTeSys Deca | 1.6…2.5 A | 6 kV | DCAC |
| LRD16 | TeSysTeSys Deca | 9…13 A | 6 kV | DCAC |
| LRD21 | TeSysTeSys Deca | 12…18 A | 6 kV | ACDC |
| LRD06 | TeSysTeSys Deca | 1…1.6 A | 6 kV | DCAC |
| LRD05 | TeSysTeSys Deca | 0.63…1 A | 6 kV | ACDC |
| LRD12 | TeSysTeSys Deca | 5.5…8 A | 6 kV | DCAC |
| LRD32 | TeSysTeSys Deca | 23…32 A | 6 kV | ACDC |
| LRD350 | TeSysTeSys Deca | 37…50 A | 6 kV | DCAC |