Schneider LRD1510 technical specifications
| Device short name | LRD |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV |
| Thermal overload class | Class 20 conforming to IEC 60947-4-1 |
| Network type | ACDC |
| Tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 6 Gn conforming to IEC 60068-2-6Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | IECULCSAEACDNV-GLLROS (Lloyds register of shipping)UKCA |
| Permissible current | 1.5 A at 240 V AC-15 for signalling circuit0.1 A at 250 V DC-13 for signalling circuit |
| Depth | 92 mm |
| Width | 45 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 4…6 A |
| Flame retardance | V1 conforming to UL 94 |
| Tightening torque | Control circuit: 1.7 N.m - on screw clamp terminalsPower circuit: 1.85 N.m - on screw clamp terminals |
| Mounting support | Plate, with specific accessoriesRail, with specific accessoriesUnder contactor |
| Relay application | Motor protection |
| Net weight | 0.19 kg |
Overview
Technical Specifications of Schneider Relay For ACDC Network Type LRD1510: Obtain a Quote for Schneider Relay For ACDC Network Type LRD1510 at economical prices. Specifications Overview for LRD1510 reveals device short name LRD, from the TeSys range. The product, known as TeSys LRDTeSys Deca, is designed for reliable thermal protection in motor control applications. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance.
Datasheet
Schneider datasheetschneider-electric-lrd1510.pdfOther models in this series
Compare LRD1510 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LRD1510 (this model) | TeSys | 4…6 A | 6 kV | ACDC |
| LRD01 | TeSysTeSys Deca | 0.1…0.16 A | 6 kV | DCAC |
| LRD4367 | TeSys | 95…120 A | 6 kV conforming to IEC 60947-1 | ACDC |
| LRD1514 | TeSys | 7…10 A | 6 kV | ACDC |
| LR2D3553 | TeSys | 23…32 A | 6 kV | ACDC |
| LRD3361 | TeSys | 55…70 A | 6 kV conforming to IEC 60947-1 | DCAC |
| LR9D5569 | TeSys | 90…150 A | 6 kV conforming to IEC 60947-1 | AC |
| LRD4369 | TeSys | 110…140 A | 6 kV conforming to IEC 60947-1 | DCAC |
| LRD3322 | TeSys | 17…25 A | 6 kV conforming to IEC 60947-1 | DCAC |