Image for reference. Refer to the datasheet for exact dimensions.
LR9D5367: Schneider Overload Relay With Phase Failure Sensitivity
Schneider LR9D5367, Overload Relay With Phase Failure Sensitivity. Protect motors—request a quote from IndMALL today and ensure reliable control.
- Brand
- Schneider
- Model number
- LR9D5367
- Series
- Schneider Contactors TeSys Deca Overload Relay
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LR9D5367 technical specifications
| Device short name | LR9D |
|---|---|
| Range | TeSys |
| Product name | TeSys LRDTeSys Deca |
| [Ith] conventional free air thermal current | 5 A for signalling circuit |
| Height | 118 mm |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Phase failure sensitivity | Tripping in 4 s +/- 20 % conforming to IEC 60947-4-1 |
| Temperature compensation | -20…60 °C |
| Auxiliary contact composition | 1 NO + 1 NC |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-1 |
| Thermal overload class | Class 10 conforming to IEC 60947-4-1 |
| Network type | AC |
| Tripping threshold | 1.05 +/- 0.06 In alarm conforming to IEC 60947-4-11.12 +/- 0.06 In de-energisation conforming to IEC 60947-4-1 |
| Control type | Red push-button: stopBlue push-button: reset |
| Mechanical robustness | Vibrations: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6Shocks: 13 Gn for 11 ms conforming to IEC 60068-2-7 |
| [Ue] rated operational voltage | 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1 |
| Associated fuse rating | 4 A gG for signalling circuit4 A BS for signalling circuit |
| Product certifications | ULCSACCCUKCA |
| Depth | 125 mm |
| Width | 115 mm |
| Ambient air temperature for storage | -60…70 °C |
| Climatic withstand | conforming to IACS E10 |
| Ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 |
| Dielectric strength | 1.89 kV at 50 Hz conforming to IEC 60947-1 |
| Thermal protection adjustment range | 60…100 A |
| Tightening torque | Alarm circuit: 0.45 N.m - on screw clamp terminalsPower circuit: 18 N.m - on bars M8Control circuit: 1.2 N.m - on screw clamp terminals |
| Mounting support | Under contactorRail |
| Relay application | Motor protection |
| Net weight | 0.885 kg |
Overview
Technical Specifications of Schneider Overload Relay With Phase Failure Sensitivity LR9D5367: Mail Us for your needs in Schneider Overload Relay With Phase Failure Sensitivity LR9D5367 with budget-friendly prices. The Main Technical Parameters of LR9D5367 include device short name LR9D, from the TeSys range. It has a conventional free air thermal current [Ith] of 5 A for signalling circuit, making it suitable for demanding environments. With a height of 118 mm and an IP20 conforming to IEC 60529, it provides protection against solid objects. The sensor operates efficiently in ambient temperatures ranging from -20…60 °C, with temperature compensation to maintain performance. It supports both AC network types.
Datasheet
Schneider datasheetschneider-electric-lr9d5367.pdfOther models in this series
Compare LR9D5367 with similar models in the same series. See all 107 models on the Schneider Contactors TeSys Deca Overload Relay page.
| Model | Range | Thermal protection adjustment range | [Uimp] rated impulse withstand voltage | Network type |
|---|---|---|---|---|
| LR9D5367 (this model) | TeSys | 60…100 A | 6 kV conforming to IEC 60947-1 | AC |
| LRD03 | TeSysTeSys Deca | 0.25…0.4 A | 6 kV | ACDC |
| LRD3355 | TeSys | 30…40 A | 6 kV conforming to IEC 60947-1 | DCAC |
| LRD063 | TeSysTeSys Deca | 1…1.6 A | 6 kV | DCAC |
| LRD3353 | TeSys | 23…32 A | 6 kV conforming to IEC 60947-1 | ACDC |
| LRD380 | TeSysTeSys Deca | 62…80 A | 6 kV | ACDC |
| LRD123 | TeSysTeSys Deca | 5.5…8 A | 6 kV | ACDC |
| LRD083 | TeSysTeSys Deca | 2.5…4 A | 6 kV | ACDC |
| LR9D5369 | TeSys | 90…150 A | 6 kV conforming to IEC 60947-1 | AC |