Image for reference. Refer to the datasheet for exact dimensions.
LP4K09013BW3: Schneider NC 24V DC TeSys K Contactor
Schneider LP4K09013BW3, NC 24V DC TeSys K Contactor. Ensure efficiency—ask IndMALL for a custom quote today and optimize your control solutions.
- Brand
- Schneider
- Model number
- LP4K09013BW3
- Series
- Schneider Contactors TeSys K Contactors
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider LP4K09013BW3 technical specifications
| Connections - terminals | Spring terminals 1 cable(s) 0.75…1.5 mm²solidSpring terminals 1 cable(s) 0.75…1.5 mm²flexible without cable endSpring terminals 2 cable(s) 0.75…1.5 mm²flexible without cable end |
|---|---|
| [Uc] control circuit voltage | 24 V DC |
| Minimum switching voltage | 17 V for signalling circuit |
| contactor application | Motor controlResistive load |
| Width | 45 mm |
| Control circuit type | DC wide range |
| Average impedance | 3 mOhm - Ith 16 A 50 Hz for power circuit |
| Depth | 57 mm |
| [Ie] rated operational current | 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit20 A (at <60 °C) at <= 690 V AC AC-1 for power circuit |
| Auxiliary contacts type | type instantaneous 1 NC |
| poles description | 3P |
| Auxiliary contact composition | 1 NC |
| IP degree of protection | IP2X |
| [Ui] rated insulation voltage | Power circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14 |
| Operating altitude | 2000 m without derating |
| Ambient air temperature for operation | -25…50 °C |
| Power pole contact composition | 3 NO |
| Hold-in power consumption in W | 1.8 W at 20 °C |
| Ambient air temperature for storage | -50…80 °C |
| Utilisation category | AC-3AC-3eAC-1AC-4 |
| Insulation resistance | > 10 MOhm for signalling circuit |
| Heat dissipation | 1.8 W |
| Hold-in power consumption in VA | - |
| Net weight | 0.235 kg |
| Minimum switching current | 5 mA for signalling circuit |
| Mounting support | RailPlate |
| Operating time | 10...20 ms coil de-energisation and NO opening30...40 ms coil energisation and NO closing |
| Rated breaking capacity | 110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947 |
| Product or component type | Contactor |
| Tightening torque | - |
| Maximum operating rate | 3600 cyc/h |
| Range | TeSys |
| [Ue] rated operational voltage | Power circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz |
| Height | 58 mm |
| Motor power kW | 2.2 kW at 220...230 V AC 50/60 Hz AC-34 kW at 380...415 V AC 50/60 Hz AC-34 kW at 440/690 V AC 50/60 Hz AC-32.2 kW at 220...230 V AC 50/60 Hz AC-3e4 kW at 380...415 V AC 50/60 Hz AC-3e4 kW at 440/690 V AC 50/60 Hz AC-3e2.2 kW at 220...230 V AC 50/60 Hz AC-44 kW at 380...415 V AC 50/60 Hz AC-44 kW at 440/690 V AC 50/60 Hz AC-4 |
| Inrush power in W | 1.8 W (at 20 °C) |
| [Uimp] rated impulse withstand voltage | 8 kV |
| Electrical durability | 1.3 Mcycles 9 A AC-3 at Ue <= 440 V1.3 Mcycles 9 A AC-3e at Ue <= 440 V0.16 Mcycles 20 A AC-1 at Ue <= 690 V0.02 Mcycles 54 A AC-4 at Ue <= 440 V |
| Device short name | LP4K |
Overview
Technical Specifications of Schneider NC 24V DC TeSys K Contactor LP4K09013BW3: Please speak to our Technical Engineer for Schneider NC 24V DC TeSys K Contactor LP4K09013BW3 at attractive prices. Technical Specs Summary of LP4K09013BW3 includes control circuit voltage [Uc] operates at 24 V DC, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments. Heat dissipation 1.3 W, it is energy efficient. Product or component type Contactor. We lead with pricing that's more favorable and support that's more attentive than other Suppliers & Traders.
Datasheet
Schneider datasheetschneider-electric-lp4k09013bw3.pdfOther models in this series
Compare LP4K09013BW3 with similar models in the same series. See all 120 models on the Schneider Contactors TeSys K Contactors page.
| Model | [Uc] control circuit voltage | Minimum switching voltage | Hold-in power consumption in VA | Hold-in power consumption in W |
|---|---|---|---|---|
| LP4K09013BW3 (this model) | 24 V DC | 17 V for signalling circuit | - | 1.8 W at 20 °C |
| LP1K09105BD | 24 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0910ED | 48 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0910GD | 125 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K0910SD | 72 V DC | 17 V for signalling circuit | - | 3 W at 20 °C |
| LP1K12004BD | 24 V DC | - | - | 3 W at 20 °C |
| LP4K0610FW3 | 110 V DC | 17 V for signalling circuit | - | 1.8 W at 20 °C |
| LP4K09004BW3 | 24 V DC | - | - | 1.8 W at 20 °C |
| LP4K09103BW3 | 24 V DC | 17 V for signalling circuit | - | 1.8 W at 20 °C |