LC1K0601M7: Schneider TeSys K contactor 3P 230 V AC Coil

Image for reference. Refer to the datasheet for exact dimensions.

LC1K0601M7: Schneider TeSys K contactor 3P 230 V AC Coil

Schneider LC1K0601M7, TeSys K contactor 3P 230V AC Coil. Optimize control—ask IndMALL for pricing today and enhance your system’s performance.

Brand
Schneider
Model number
LC1K0601M7
Series
Schneider Contactors TeSys K Contactors

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Schneider LC1K0601M7 technical specifications

Connections - terminalsScrew clamp terminals 1 cable(s) 1.5…4 mm²solidScrew clamp terminals 1 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 1 cable(s) 0.34…2.5 mm²flexible with cable endScrew clamp terminals 2 cable(s) 1.5…4 mm²solidScrew clamp terminals 2 cable(s) 0.75…4 mm²flexible without cable endScrew clamp terminals 2 cable(s) 0.34…1.5 mm²flexible with cable end
[Uc] control circuit voltage220...230 V AC 50/60 Hz
Minimum switching voltage17 V for signalling circuit
contactor applicationMotor control
Width45 mm
Control circuit typeAC at 50/60 Hz
Average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
Depth57 mm
[Ie] rated operational current6 A (at <60 °C) at <= 440 V AC AC-3 for power circuit6 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Auxiliary contacts typetype instantaneous 1 NC
poles description3P
Auxiliary contact composition1 NC
IP degree of protectionIP2X conforming to VDE 0106
[Ui] rated insulation voltagePower circuit: 600 V conforming to UL 508Power circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-4-1Signalling circuit: 690 V conforming to IEC 60947-5-1Signalling circuit: 600 V conforming to UL 508Power circuit: 600 V conforming to CSA C22.2 No 14Signalling circuit: 600 V conforming to CSA C22.2 No 14
Operating altitude2000 m without derating
Ambient air temperature for operation-
Power pole contact composition3 NO
Hold-in power consumption in W-
Ambient air temperature for storage-50…80 °C
Utilisation categoryAC-3AC-3eAC-4
Insulation resistance> 10 MOhm for signalling circuit
Heat dissipation1.3 W
Hold-in power consumption in VA4.5 VA (at 20 °C)
Net weight0.18 kg
Minimum switching current5 mA for signalling circuit
Mounting supportPlateRail
Operating time10...20 ms coil de-energisation and NO opening10...20 ms coil energisation and NO closing
Rated breaking capacity110 A at 220...230 V conforming to IEC 60947110 A at 380...400 V conforming to IEC 60947110 A at 415 V conforming to IEC 60947110 A at 440 V conforming to IEC 6094780 A at 500 V conforming to IEC 6094770 A at 660...690 V conforming to IEC 60947
Product or component typeContactor
Tightening torque0.8…1.3 N.m - on screw clamp terminals Philips No 20.8…1.3 N.m - on screw clamp terminals flat Ø 6 mm0.8…1.3 N.m - on screw clamp terminals pozidriv No 2
Maximum operating rate3600 cyc/h
RangeTeSys
[Ue] rated operational voltagePower circuit: <= 690 V AC <= 400 HzSignalling circuit: <= 690 V AC <= 400 Hz
Height58 mm
Motor power kW1.5 kW at 220...230 V AC 50/60 Hz AC-32.2 kW at 380...415 V AC 50/60 Hz AC-33 kW at 440/690 V AC 50/60 Hz AC-31.5 kW at 220...230 V AC 50/60 Hz AC-3e2.2 kW at 380...415 V AC 50/60 Hz AC-3e3 kW at 440/690 V AC 50/60 Hz AC-3e1.5 kW at 220...230 V AC 50/60 Hz AC-42.2 kW at 380...415 V AC 50/60 Hz AC-43 kW at 440/690 V AC 50/60 Hz AC-4
Inrush power in W-
[Uimp] rated impulse withstand voltage8 kV
Electrical durability1.3 Mcycles 6 A AC-3 at Ue <= 440 V1.3 Mcycles 6 A AC-3e at Ue <= 440 V0.05 Mcycles 36 A AC-4 at Ue <= 440 V
Device short nameLC1K
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

Technical Specifications of Schneider TeSys K contactor 3P 230 V AC Coil LC1K0601M7: Ask for the Pricing of Schneider TeSys K contactor 3P 230 V AC Coil LC1K0601M7 at unbeatable prices. Detailed Specifications of LC1K0601M7 features control circuit voltage [Uc] operates at 220...230 V AC 50/60 Hz, with a minimum switching voltage of 17 V for signalling circuit, ensuring responsive operation. The control circuit type is AC at 50/60 Hz, and the auxiliary contacts are type instantaneous 1 NC configuration, providing reliable switching. The sensor features a 3P design and operates at altitudes up to 2000 m without derating, ensuring versatility across various environments.

Datasheet

Schneider datasheetschneider-electric-lc1k0601m7.pdf

Other models in this series

Compare LC1K0601M7 with similar models in the same series. See all 120 models on the Schneider Contactors TeSys K Contactors page.

LC1K0601M7 compared with other models in the series
Model[Uc] control circuit voltageMinimum switching voltageHold-in power consumption in VAHold-in power consumption in W
LC1K0601M7 (this model)220...230 V AC 50/60 Hz17 V for signalling circuit4.5 VA (at 20 °C)-
LC1K0901M7220...230 V AC 50/60 Hz17 V for signalling circuit4.5 VA (at 20 °C)-
LC1K09008E748 V AC 50/60 Hz-4.5 VA (at 20 °C)-
LP1K0901BD24 V DC17 V for signalling circuit-3 W at 20 °C
LC1K09008B724 V AC 50/60 Hz-4.5 VA (at 20 °C)-
LC1K0601B724 V AC 50/60 Hz17 V for signalling circuit4.5 VA (at 20 °C)-
LC1K0610F7110 V AC 50/60 Hz17 V for signalling circuit4.5 VA (at 20 °C)-
LC1K1210M7220...230 V AC 50/60 Hz17 V for signalling circuit4.5 VA (at 20 °C)-
LP1K0910FD110 V DC17 V for signalling circuit-3 W at 20 °C