Schneider Electric CAE22Q5 technical specifications
| Range | Easy TeSys |
|---|---|
| Product or component type | Control relay |
| Device short name | CAE |
| Contactor Application | Control circuit |
| Colour | Grey (RAL 7011) |
| Pole contact composition | 2 NO + 2 NC |
| [Ue] rated operational voltage | <= 690 V AC |
| Control circuit type | AC at 50 Hz |
| [Uc] control circuit voltage | 380 V AC 50 Hz |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947 |
| Operating Altitude | 3000 m without derating |
| [Ith] conventional free air thermal current | 10 A (at 40 °C) |
| Irms rated making capacity | 140 A at 690 V AC conforming to IEC 60947-5-1 |
| [Icw] rated short-time withstand current | 120 A - 500 ms140 A - 100 ms |
| Associated fuse rating | 10 A gG at 690 V conforming to IEC 60947-5-1 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1 |
| Mounting Support | PlateRail |
| Connections - terminals | Screw clamp terminals 1 1…2.5 mm² - cable stiffness: flexible without cable endScrew clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable endScrew clamp terminals 1 1…2.5 mm² - cable stiffness: flexible with cable endScrew clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable endScrew clamp terminals 1 1…2.5 mm² - cable stiffness: solid without cable endScrew clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end |
| Recommended tightening torque | 1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc at 50 HzDrop-out: 0.3...0.6 Uc |
| Operating time | 4...19 ms coil energisation and NC opening12...22 ms coil energisation and NO closing4...12 ms coil de-energisation and NC opening6...17 ms coil de-energisation and NO closing |
| Inrush power in VA | 70 VA 50 Hz (at 20 °C) |
| Hold-in power consumption in VA | 8 VA 50 Hz (at 20 °C) |
| Minimum switching voltage | 17 V |
| Minimum switching current | 5 mA |
| Insulation resistance | > 10 MOhm |
| Height | 74 mm |
| Width | 45 mm |
| Depth | 80 mm |
| Net weight | 0.28 kg |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Ambient air temperature for operation | -20…70 °C |
| Ambient air temperature for storage | -60…80 °C |
| Operating altitude | 3000 m without derating |
Overview
The Schneider CAE22Q5 Control Relay offers a Easy TeSys Control relay , PlateRail mounting support. This Control relay features a pole contact composition of 2 NO + 2 NC and operates with an operational voltage of up to <= 690 V AC, making it ideal for a wide range of industrial applications. The relay’s rated impulse withstand voltage is 6 kV conforming to IEC 60947 standards. Inrush power consumption is 70 VA 50 Hz (at 20 °C), with hold-in power consumption at 8 VA 50 Hz (at 20 °C). The minimum switching voltage is 17 V, and the minimum switching current is 5 mA.
Datasheet
Schneider Electric datasheetschneider-electric-cae22q5.pdfOther models in this series
Compare CAE22Q5 with similar models in the same series. See all 16 models on the Schneider Contactors EasyPact TVS Control Relay page.
| Model | [Uc] control circuit voltage | Pole contact composition | Mounting Support |
|---|---|---|---|
| CAE22Q5 (this model) | 380 V AC 50 Hz | 2 NO + 2 NC | PlateRail |
| CAE22B5 | 24 V AC 50 Hz | 2 NO + 2 NC | RailPlate |
| CAE22F5 | 110 V AC 50 Hz | 2 NO + 2 NC | PlateRail |
| CAE22M5 | 220 V AC 50 Hz | 2 NO + 2 NC | RailPlate |
| CAE22N5 | 415 V AC 50 Hz | 2 NO + 2 NC | RailPlate |
| CAE22U5 | 240 V AC 50 Hz | 2 NO + 2 NC | RailPlate |
| CAE31B5 | 24 V AC 50 Hz | 3 NO + 1 NC | RailPlate |
| CAE31F5 | 110 V AC 50 Hz | 3 NO + 1 NC | PlateRail |
| CAE31M5 | 220 V AC 50 Hz | 3 NO + 1 NC | PlateRail |