Schneider ATV6A0C11Q4 technical specifications
| Degree of protection | - |
|---|---|
| Supply frequency | 50...60 Hz - 5...5 % |
| Vibration resistance | 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-60.5 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| IP degree of protection | IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529 |
| Speed drive output frequency | 0…500 Hz |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-41.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Product or component type | Variable speed drive |
| Output voltage | <= power supply voltage |
| Asynchronous motor control profile | Constant torque standardVariable torque standardOptimized torque mode |
| Mounting mode | Cabinet mount |
| Ambient air temperature for storage | -40…70 °C |
| Continuous output current | 211.0 A at 2.5 kHz normal duty173.0 A at 2.5 kHz heavy duty |
| Relay output type | Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cyclesConfigurable relay logic R2: sequence relay NO electrical durability 100000 cyclesConfigurable relay logic R3: sequence relay NO electrical durability 100000 cycles |
| Minimum switching current | Relay output R1, R2, R3: 5 mA at 24 V DC |
| Electrical connection | Control: removable screw terminals 0.5...1.5 mm²/AWG 20...AWG 16Line side: screw terminalMotor: M10 x 2 bars |
| Synchronous motor control profile | Permanent magnet motor |
| Physical interface | 2-wire RS 485 for Modbus serial |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Type of polarization | No impedance for Modbus serial |
| Product destination | Synchronous motorsAsynchronous motors |
| Number of preset speeds | 16 preset speeds |
| Operating altitude | <= 1000 m without derating1000...4800 m with current derating 1 % per 100 m |
| Apparent power | 137 kVA at 400 V normal duty116 kVA at 400 V heavy duty |
| [Us] rated supply voltage | 400 V - 15...10 % |
| Ambient air temperature for operation | -10…40 °C without derating40…50 °C with derating factor |
| Supply | External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protectionInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protectionInternal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection |
| Switching frequency | 2.5...8 kHz with derating factor2...8 kHz adjustable |
| Motor power kW | 110.0 kW at 400 V normal duty90.0 kW at 400 V heavy duty |
| EMC filter | Integrated with 300 m conforming to IEC 61800-3 category C3 |
| Communication port protocol | EthernetModbus serialModbus TCP |
| Analogue input type | AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bitsAI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits |
| Maximum switching current | Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V ACRelay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DCRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V ACRelay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC |
| Range of product | Altivar Process ATV600 |
| Shock resistance | 7 gn for 11 ms conforming to IEC 60068-2-27 |
| Power dissipation in W | Forced convection: 2850 W, switching frequency 2.5 kHz (normal duty)Forced convection: 2240 W, switching frequency 2.5 kHz (heavy duty) |
| Nominal switching frequency | 2.5 kHz |
| Motor power hp | - |
| Network number of phases | 3 phases |
Overview
The Schneider ATV6A0C11Q4 Variable Speed Drive offers a 110.0 kW at 400 V normal duty90.0 kW at 400 V heavy duty motor power, 2-wire RS 485 for Modbus serial , 3 phases . Engineered for industrial applications such as water treatment, HVAC, oil & gas, and material handling, this ATV600 series 3-phase VFD ensures high-performance motor control with integrated EMC compliance and advanced Modbus and Ethernet communication support. Designed for cabinet mount integration (IP00), the ATV6A0C11Q4 offers power dissipation up to 2850 W (normal duty) and includes analog input configurations for voltage (0–10 V) and current (0–20 mA).
Datasheet
Schneider datasheetschneider-electric-atv6a0c11q4.pdfOther models in this series
Compare ATV6A0C11Q4 with similar models in the same series. See all 106 models on the Altivar ATV600 page.
| Model | Range of product | [Us] rated supply voltage | Minimum switching current | Communication port protocol |
|---|---|---|---|---|
| ATV6A0C11Q4 (this model) | Altivar Process ATV600 | 400 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |
| ATV6A0C11N6 | Altivar Process ATV600 | 500 V - 10...15 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C11Q6 | Altivar Process ATV600 | 690 V - 15...10 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C11R4 | Altivar Process ATV600 | 440 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |
| ATV6A0C11S6 | Altivar Process ATV600 | 600 V - 15...10 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C11T4 | Altivar Process ATV600 | 480 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |
| ATV6A0C11T6 | Altivar Process ATV600 | 600 V - 15...10 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C13N6 | Altivar Process ATV600 | 500 V - 10...15 % | - | EthernetModbus serialModbus TCP |
| ATV6A0C13Q4 | Altivar Process ATV600 | 400 V - 15...10 % | Relay output R1, R2, R3: 5 mA at 24 V DC | EthernetModbus serialModbus TCP |