Image for reference. Refer to the datasheet for exact dimensions.
Schneider ATV310HD22N4EF Variable Speed Drive
Schneider ATV310HD22N4EF, Altivar 22kW Heavy Duty VFD. Reliable control—request your IndMALL quote today for efficient Schneider VFD solutions.
- Brand
- Schneider
- Model number
- ATV310HD22N4EF
- Series
- Altivar 310
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider ATV310HD22N4EF technical specifications
| Minimum switching current | 5 mA at 24 V DC for logic relay |
|---|---|
| Analogue output number | 1 |
| Height | 390 mm |
| Speed drive output frequency | 0.5…400 Hz |
| Unit Type of Package 2 | P06 |
| Time constant | 20 ms +/- 1 ms for reference change |
| Operating altitude | <= 1000 m without derating |
| Number of addresses | 1…247 for Modbus |
| Supply frequency | 50/60 Hz +/- 5 % |
| Device short name | ATV310 |
| Acceleration and deceleration ramps | Linear from 0...999.9 sSU |
| Speed range | 1…20 for asynchronous motor |
| Physical interface | 2-wire RS 485 for Modbus |
| Product or component type | Variable speed drive |
| Ambient air temperature for storage | -25…70 °C |
| Analogue input number | 1 |
| Output voltage | 380...460 V three phase |
| Continuous output current | 46 A heavy duty60 A normal duty |
| Package 2 Weight | 80.2 kg |
| Asynchronous motor control profile | Voltage/frequency ratio (V/f)Voltage/frequency ratio - Energy Saving, quadratic U/fSensorless vector control (SVC) |
| Electrical connection | Terminal, clamping capacity: 25...35 mm², AWG 3...AWG 2 (L1, L2, L3, PA/+, PB, U, V, W) |
| Maximum switching current | 2 A at 250 V AC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay2 A at 30 V DC on inductive load cos phi = 0.4 L/R = 7 ms for logic relay3 A at 250 V AC on resistive load cos phi = 1 L/R = 0 ms for logic relay4 A at 30 V DC on resistive load cos phi = 1 L/R = 0 ms for logic relay |
| Electromagnetic compatibility | Electrical fast transient/burst immunity test - test level: level 4 conforming to IEC 61000-4-4Electrostatic discharge immunity test - test level: level 3 conforming to IEC 61000-4-2Immunity to conducted disturbances - test level: level 3 conforming to IEC 61000-4-6Radiated radio-frequency electromagnetic field immunity test - test level: level 3 conforming to IEC 61000-4-3Voltage dips and interruptions immunity test conforming to IEC 61000-4-11Surge immunity test - test level: level 3 conforming to IEC 61000-4-5 |
| Motor slip compensation | Adjustable |
| Supply | Internal supply for reference potentiometer: 5 V (4.75…5.25 V)DC, <10 mA with overload and short-circuit protectionInternal supply for logic inputs: 24 V (20.4…28.8 V)DC, <100 mA with overload and short-circuit protection |
| Braking torque | Up to 150 % of nominal motor torque with braking resistorUp to 70 % of nominal motor torque without braking resistor |
| Number of Units in Package 1 | 1 |
| Width | 180 mm |
| Package 1 Weight | 10.7 kg |
| Range of product | Easy Altivar 310 |
| Depth | 212 mm |
| Operating position | Vertical +/- 10 degree |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Communication service | Read holding registers (03) 29 wordsWrite single register (06) 29 wordsWrite multiple registers (16) 27 wordsRead/write multiple registers (23) 4/4 wordsRead device identification (43) |
| Quantity per set | Set of 1 |
Overview
The Schneider ATV310HD22N4EF is a rugged Altivar 22 kW Heavy Duty VFD from Schneider Electric , a global automation leader known for high-efficiency and precision-engineered motor-control solutions. The ATV310HD22N4EF operates on a 380 – 460 V three-phase supply and delivers a continuous output current of 46 A (heavy duty) and 60 A (normal duty) . The unit measures 390 mm (H) × 180 mm (W) × 212 mm (D) and features an integrated RS-485 Modbus RTU interface with RJ45 connector for seamless PLC and SCADA communication. Pump systems benefit from smooth pressure regulation and reduced water-hammer effects. For complete documentation, download the official ATV310HD22N4EF datasheet and ATV310HD22N4EF manual .
Datasheet
Schneider datasheetschneider-electric-atv310hd22n4ef.pdfOther models in this series
Compare ATV310HD22N4EF with similar models in the same series. See all 15 models on the Altivar 310 page.
| Model | Continuous output current | Depth | Height | Width |
|---|---|---|---|---|
| ATV310HD22N4EF (this model) | 46 A heavy duty60 A normal duty | 212 mm | 390 mm | 180 mm |
| ATV310HU55N4E | 12.6 A heavy duty16.0 A normal duty | 151 mm | 184 mm | 140 mm |
| ATV310HU75N4E | 17 A heavy duty22.8 A normal duty | 171 mm | 232 mm | 150 mm |
| ATV310HD11N4E | 24 A heavy duty30 A normal duty | 171 mm | 232 mm | 150 mm |
| ATV310HD15N4E | 33 A heavy duty36 A normal duty | 191 mm | 330 mm | 180 mm |
| ATV310HD18N4E | 39 A heavy duty43 A normal duty | 191 mm | 330 mm | 180 mm |
| ATV310HD22N4E | 46 A heavy duty60 A normal duty | 212 mm | 390 mm | 180 mm |
| ATV310HD15N4EF | 33 A heavy duty36 A normal duty | 191 mm | 330 mm | 180 mm |
| ATV310HD18N4EF | 39 A heavy duty43 A normal duty | 191 mm | 330 mm | 180 mm |