Image for reference. Refer to the datasheet for exact dimensions.
A9N61518: Schneider C60H 1 Pole 50A C Curve Breaker
Schneider A9N61518, C60H 1 Pole 50A C Curve Breaker. Protect equipment—request a quote from IndMALL today for trusted breaker solutions.
- Brand
- Schneider
- Model number
- A9N61518
- Series
- Schneider Contactors Acti 9 C60H-DC
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Schneider A9N61518 technical specifications
| Range | Acti9 |
|---|---|
| Product or component type | Miniature circuit-breaker |
| Device short name | C60H-DC |
| Device application | Distribution |
| Poles description | 1P |
| Number of protected poles | 1 |
| [In] rated current | 50 A at 25 °C |
| Network type | DC |
| Trip unit technology | Thermal-magnetic |
| Breaking capacity | 10 kA Icu at 220 V DC conforming to EN 60947-210 kA Icu at 220 V DC conforming to IEC 60947-26 kA Icu at 250 V DC conforming to EN 60947-26 kA Icu at 250 V DC conforming to IEC 60947-220 kA Icu at 110 V DC conforming to EN 60947-220 kA Icu at 110 V DC conforming to IEC 60947-2 |
| Utilisation category | Category A conforming to EN 60947-2Category A conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2Yes conforming to EN 60947-2 |
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 250 V DC |
| [Ui] rated insulation voltage | 500 V DC conforming to IEC 60947-2500 V DC conforming to EN 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN 60947-26 kV conforming to IEC 60947-2 |
| Contact position indicator | Yes |
| Control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| Net weight | 0.128 kg |
| Colour | White |
| Tightening torque | Power circuit: 2.5 N.m top or bottom |
| Pollution degree | 3 conforming to EN 60947-23 conforming to IEC 60947-2 |
| Operating altitude | 2000 m |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
Overview
Technical Specifications of Schneider C60H 1 Pole 50A C Curve Breaker A9N61518: Obtain a Quote for Schneider C60H 1 Pole 50A C Curve Breaker A9N61518 at economical prices. Specifications Overview for A9N61518 reveals the product is a Miniature circuit-breaker with a rated current of 50 A at 25 °C, designed specifically for DC applications. It supports an operational voltage of 250 V DC and an insulation voltage of 500 V DC conforming to IEC 60947-2500 V DC conforming to EN 60947-2 standards. The Acti9 C60H-DC is designed for Fixed installation on a 35 mm symmetrical DIN rail, making it ideal for industrial and commercial environments.
Datasheet
Schneider datasheetschneider-electric-a9n61518.pdfOther models in this series
Compare A9N61518 with similar models in the same series. See all 33 models on the Schneider Contactors Acti 9 C60H-DC page.
| Model | [Ue] rated operational voltage | [In] rated current | Number of protected poles | Poles description |
|---|---|---|---|---|
| A9N61518 (this model) | 250 V DC | 50 A at 25 °C | 1 | 1P |
| A9N61512 | 250 V DC | 20 A at 25 °C | 1 | 1P |
| A9N61513 | 250 V DC | 25 A at 25 °C | 1 | 1P |
| A9N61515 | 250 V DC | 32 A at 25 °C | 1 | 1P |
| A9N61517 | 250 V DC | 40 A at 25 °C | 1 | 1P |
| A9N61519 | 250 V DC | 63 A at 25 °C | 1 | 1P |
| A9N61520 | 500 V DC | 0.5 A at 25 °C | 2 | 2P |
| A9N61521 | 500 V DC | 1 A at 25 °C | 2 | 2P |