Image for reference. Refer to the datasheet for exact dimensions.
Puls CP5.121 Power Supply
Send Your Inquiry for Puls 1 Phase Power Supplies CP5.121 with the special pricing. 0.91, 12 Vdc, 120 W, DIN rail.
- Brand
- Puls
- Model number
- CP5.121
- Series
- Puls DIN Rail Power Supply
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Puls CP5.121 technical specifications
| AC Input voltage | AC 100 - 240 V (-15 %/+10 %) |
|---|---|
| DC Input voltage | DC 110 V - 150 V (± 20 %) |
| Harmonic correction | active |
| Power factor | 0.91 |
| Input inrush current limitation | active |
| Input inrush current | 4 A / 4 A |
| External input fuse recommendation | B-6 A / C-6 A |
| Nominal voltage | 12 Vdc |
| Adjustment range | 12 - 15 V |
| Output current range | 10 - 8 A |
| Output current | 8 A at 15 V |
| Output power | 120 W |
| Derating | 3 W/°C for >60 °C |
| Ripple and noise voltage max. | 50 mVpp |
| Dimensions (WxHxD) | 32 mm x 124 mm x 102 mm |
| Weight per unit (excl. packaging) | 440 g |
| Mounting method | DIN rail |
| Operating temp. range | -25 °C to 70 °C |
| Connection method | Screw terminals |
| Efficiency, typ. | 94 % |
| Power losses, typ. | 7.7 W |
Overview
The Puls CP5.121 Power Supply offers 12 Vdc, DIN rail Mounting Method, Screw terminals Connection Method, 8 A at 15 V output current. The Puls CP5.121 is engineered with precision, supporting an input range of AC 100–240 V and DC 110–150 V with active inrush current limitation of just 4 A . Its rugged design supports a wide operating range from -25 °C to +70 °C, with derating safeguards above 60 °C. Engineers often review the CP5.121 manual , analyze the CP5.121 datasheet , and compare CP5.121 price before procurement. Whether searched as Puls CP5.121 or CP5 121 , this model is trusted globally for its quality and reliability.
Datasheet
Puls datasheetcp5-121.pdfOther models in this series
Compare CP5.121 with similar models in the same series. See all 193 models on the Puls DIN Rail Power Supply page.
| Model | Mounting method | Operating temp. range | Output current range | Connection method |
|---|---|---|---|---|
| CP5.121 (this model) | DIN rail | -25 °C to 70 °C | 10 - 8 A | Screw terminals |
| FPT500.245-018-103 | - | -25 °C to 70 °C | 25 - 21.4 A | Input: M12-S | Output: 7/8" 4pin |
| FPT500.245-034-105 | - | -25 °C to 70 °C | 25 - 21.4 A | Input: M12-S | Output: M12-L |
| FPT500.245-034-106 | DIN rail | -25 °C to 70 °C | 25 - 21.4 A | Input: M12-S | Output: M12-L |
| FPT500.247-064-102 | DIN rail | -25 °C to 70 °C | 25 - 21.4 A | Screw terminals |
| CP5.242 | DIN rail | -25 °C to 70 °C | 5 - 4.3 A | Screw terminals |
| CP10.121 | DIN rail | -25 °C to 70 °C | 16 - 12.8 A | Screw terminals |
| CP10.122 | DIN rail | -25 °C to 70 °C | 16 - 12.8 A | Screw terminals |
| CS3.241 | DIN rail | -25 °C to 70 °C | 3.3 - 2.7 A | Screw terminals |