Phoenix Contact PT 2,5-PE/L/N/MT - 1336376 - Ground terminal block
Mail Us for Phoenix Contact Ground terminal block PT 2,5-PE/L/N/MT, 1336376 at the best rates.
- Brand
- Phoenix Contact
- Model number
- PT 2,5-PE/L/N/MT
- Series
- Phoenix Disconnect Terminal Block
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Phoenix Contact PT 2,5-PE/L/N/MT technical specifications
| Product type | Ground terminal block |
|---|---|
| DIN rail/fixing support | NS 35/15 |
| Number of connections | 8 |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Rated surge voltage | 6 kV |
| Number of connections per level | 2 |
| Nominal cross section | 2.5 mm² |
| Stripping length | 8 mm ... 10 mm |
| Internal cylindrical gage | A3 |
| Connection in acc. with standard | IEC 6094772 |
| Conductor cross section rigid | 0.34 mm² ... 4 mm² |
| Cross section AWG | 26 ... 12 (converted acc. to IEC) |
| Conductor cross section flexible | 0.5 mm² ... 2.5 mm² |
| Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.5 mm² ... 2.5 mm² |
| Nominal current | 18 A |
| Maximum load current | 20 A (with 4 mm² conductor crosssection) |
| Nominal voltage | 500 V |
| Width | 5.2 mm |
| End cover width | 2.2 mm |
| Height | 142.4 mm |
| Depth on NS 35/7,5 | 70.2 mm |
| Depth on NS 35/15 | 77.7 mm |
| Color | gray (RAL 7042) |
| Flammability rating according to UL 94 | V0 |
| Insulating material group | I |
| Insulating material | PA |
| Test voltage setpoint | 1.89 kV |
| Result | Test passed |
| Requirement temperature-rise test | Increase in temperature ⤠45 K |
| Short-time withstand current 2.5 mm² | 0.3 kA |
| Open side panel | Yes |
| DIN rail/fixing support | NS 35 |
| Rotation speed | 10 (+/ 2) rpm |
| Revolutions | 135 |
| Conductor cross section/weight | 0.14 mm² / 0.2 kg |
| Temperature cycles | 192 |
| Time of exposure | 30 s |
| Ambient temperature (operation) | 60 °C ... 110 °C (Operating temperature range incl. selfheating; for max. shortterm operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | 25 °C ... 60 °C (for a short time, not exceeding 24 h, 60 °C to +70 °C) |
| Ambient temperature (assembly) | 5 °C ... 70 °C |
| Ambient temperature (actuation) | 5 °C ... 70 °C |
| Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % |
| Mounting type | NS 35/7,5 |
| Specification | DIN EN 50155 (VDE 0115200):202206 |
| Spectrum | Service life test category 1, class B, body mounted |
| Frequency | f1 = 5 Hz to f2 = 150 Hz |
| ASD level | 0.964 (m/s²)²/Hz |
| Acceleration | 5g |
| Test duration per axis | 5 h |
| Test directions | X, Y and Zaxis (pos. and neg.) |
| Pulse shape | Halfsine |
| Shock duration | 30 ms |
| Number of shocks per direction | 3 |
| Number of positions | 4 |
| Conductor cross section, rigid [AWG] | 20 ... 12 (converted acc. to IEC) |
Overview
Technical Specifications of Ground terminal block PT 2,5-PE/L/N/MT 1336376
Other models in this series
Compare PT 2,5-PE/L/N/MT with similar models in the same series. See all 300 models on the Phoenix Disconnect Terminal Block page.
| Model | Number of connections | Number of connections per level | Overvoltage category | Rated surge voltage |
|---|---|---|---|---|
| PT 2,5-PE/L/N/MT (this model) | 8 | 2 | III | 6 kV |
| ZDMTK 2,5 BU | 4 | 2 | III | 6 kV |
| UT 4-PE/L/HEDI | 5 | 2 | III | 6 kV |
| UT 4-TG-P/P-EX | 2 | 2 | III | 6 kV |
| PT 1,5/S-MTD BU | 2 | 2 | III | 6 kV |
| UT 6-MT P/P BU | 2 | 2 | III | 6 kV |
| PT 2,5-TWIN-MT-CLT | 3 | 3 | III | 4 kV |
| UT 4-MTL KNIFE-RD | 2 | 2 | III | 6 kV |
| TBPC 2,5-MT | 2 | 2 | III | 6 kV |