Image for reference. Refer to the datasheet for exact dimensions.
Omron TL-N20MY2 2M Proximity Sensor
Omron TL-N20MY2 2M Proximity Sensor offers Inductive, Unshielded, 20 mm sensing, AC 2-Wire NC, Pre Wired Cable Length 2M, 100 to 220 VAC.
- Brand
- Omron
- Model number
- TL-N20MY2 2M
- Series
- TL Series
- Product type
- Proximity Sensors
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron TL-N20MY2 2M technical specifications
| Sensor | Rectangular |
|---|---|
| Mounting | Unshielded |
| Sensing Distance | 20 mm |
| Setting Distance | 0 to 16 mm |
| Output Configuration | AC 2-Wire |
| Operation Mode | NC |
| Connection | Pre Wired Cable Length 2M |
| Power Supply Voltage | 100 to 220 VAC |
| Standard Target | 50 × 50 × 1 mm |
| Differential Travel | 15% max. of sensing distance |
| Detectable Object | Ferrous metal (The sensing distance decreases with non-ferrous metal.) |
| Response Frequency | 10 Hz |
| Indicator | Operation indicator (red) |
| Protection Circuit | Surge suppressor |
| Ambient Temperature Range | Operating: −25 to 70°C, Storage: −40 to 85°C (with no icing or condensation) |
| Ambient Humidity Range | Operating/Storage: 35% to 95% (with no condensation) |
| Insulation Resistance | ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C |
| Dielectric Strength | 50 MΩ min. (at 500 VDC) between current-carrying parts and case |
| Vibration Resistance | Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
| Shock Resistance | Destruction: 500 m/s2 10 times each in X, Y, and Z directions |
| Voltage Influence | ±1% max. of sensing distance at rated voltage in rated voltage ±10% range |
| Degree Of Protection | IP67 |
| Weight | Approx. 340 g |
Overview
Omron TL-N20MY2 2M is a rectangular, unshielded inductive proximity sensor with a 20 mm sensing distance and a 0 to 16 mm setting distance. It uses an AC 2-wire NC output through a pre-wired 2 m cable and operates from 100 to 220 VAC. Insulation resistance is 50 MΩ min. at 500 VDC, dielectric strength is 2,000 VAC for 1 minute, and voltage influence is ±1% max. within rated voltage ±10%. For another TL rectangular sensor using a pre-wired 2 m cable and AC 2-wire operation but a shorter 5 mm sensing distance with NO switching, see TL-N5MY1 2M.
Datasheet
Omron datasheettl-n-q-datasheet.pdfOther models in this series
Compare TL-N20MY2 2M with similar models in the same series. See all 20 models on the TL Series page.
| Model | Dia | Sensing Distance | Output | Connection | Installation |
|---|---|---|---|---|---|
| TL-N20MY2 2M (this model) | Rectangular | 20 mm | AC 2-wire, NC | Cable, 2 m | Non-flush (Unshielded) |
| TL-N20MD1 2M | Rectangular | 20 mm | DC 2-wire, NO | Cable, 2 m | Non-flush (Unshielded) |
| TL-N20ME1 2M | Rectangular | 20 mm | NPN, NO | Cable, 2 m | — |
| TL-N20ME2 2M | Rectangular | 20 mm | NPN, NC | Cable, 2 m | — |
| TL-N20MY1 2M | Rectangular | 20 mm | AC 2-wire, NO | Cable, 2 m | — |
| TL-N5ME1 2M | Rectangular | 5 mm | NPN, NO | Cable, 2 m | — |
| TL-N10MF1 2M | Rectangular | 10 mm | PNP, NO | Cable, 2 m | Non-flush (Unshielded) |
| TL-N5MY1 2M | Rectangular | 5 mm | AC 2-wire, NO | Cable, 2 m | Non-flush (Unshielded) |
| TL-N7MD1 2M | Rectangular | 7 mm | DC 2-wire, NO | Cable, 2 m | Non-flush (Unshielded) |