Omron S8FS-C10005 technical specifications
| Power rating | 100 W |
|---|---|
| Output voltage | 5 VDC |
| Rated output current | 20 A |
| Terminal type | Screw Terminal |
| Mounting method | DIN rail |
| Connection | Terminal blocks |
| Efficiency | 80 % typ.(at 115 VAC input) 81 % typ.(at 230 VAC input) |
| Rated input voltage | Single phase 85 to 132 VAC, 176 to 264 VAC, 248 to 373 VDC |
| Rated input current | 2 A typ.(at 115 VAC input) 1.1 A typ.(at 230 VAC input) |
| Input Leakage current | 0.35 A typ.(at 115 VAC input) 0.60 A typ.(at 230 VAC input) |
| Input Frequency | 50/60 Hz |
| Output indicator | Yes (color: green) |
| Output voltage variable range | -10% to 10% (with V. ADJ) |
| Start-up time | 710 ms max.(at 115 VAC input) 720 ms max.(at 230 VAC input) |
| Hold time | 23 ms max.(at 115 VAC input) 29 ms max.(at 230 VAC input) |
| Vibration resistance | 10 to 55 Hz, 0.375-mm half amplitude for 2 h each in X, Y, and Z directions 10 to 500 Hz, 0.26-mm half amplitude for 1 h each in X, Y, and Z directions |
| Shock resistance | 150 m/s2, 3 times each in ±X, ±Y, ±Z directions |
| Ambient temperature (Operating) | -20 to 60°C |
| Ambient temperature (Storage) | -40 to 85°C |
| Ambient humidity (OperatingStorage) | 20% to 90% (Storage humidity: 10% to 95%) |
| Cooling fan | No |
| Weight | 400 g max. |
Overview
Omron S8FS-C10005 SMPS is a 100 W switch mode power supply designed to provide 5 VDC for industrial control equipment requiring high output current. The unit operates at 50/60 Hz and supports single-phase 85 to 132 VAC, 176 to 264 VAC, or 248 to 373 VDC input. Within the S8FS-C Series, the S8FS-C10005 provides a DIN rail 100 W, 5 VDC configuration. Compare other 100W 5V power supplies from Omron automation controls . Start-up time is specified at 710 ms maximum with 115 VAC input and 720 ms maximum with 230 VAC input. Operating temperature extends from -20°C to 60°C, while storage temperature ranges from -40°C to 85°C.
Datasheet
Omron datasheets8fs-c-datasheet.pdfOther models in this series
Compare S8FS-C10005 with similar models in the same series. See all 67 models on the S8FS-C Series page.
| Model | Mounting method | Output voltage | Rated output current | Power rating |
|---|---|---|---|---|
| S8FS-C10005 (this model) | DIN rail | 5 VDC | 20 A | 100 W |
| S8FS-C07524 | DIN rail | 24 VDC | 3.2 A | 75 W |
| S8FS-C07524D | DIN rail | 24 VDC | 3.2 A | 75 W |
| S8FS-C07524J | Direct mounting | 24V | 3.2A | 75W |
| S8FS-C07548J | DIN rail | 48 VDC | 1.6 A | 75 W |
| S8FS-C10012 | Direct mounting | 12V | 8.5A | 100W |
| S8FS-C10012J | Direct mounting | 12V | 8.5A | 100W |
| S8FS-C10015D | DIN rail | 15 VDC | 7 A | 100 W |
| S8FS-C10024 | Direct mounting | 24V | 4.5A | 100W |