Image for reference. Refer to the datasheet for exact dimensions.
Omron MY4N AC220/240 Relay
Omron MY4N AC220/240 Relay features a closed-type design, plug-in terminals, 4PDT contacts, 3 A rating, LED indicator, and fast 20 ms operation/reset performance.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron MY4N AC220/240 technical specifications
| Terminal Structure | Plug-in terminal |
|---|---|
| Degree Of Protection | Closed type (cover) |
| Coil Resistance | 18790 Ω |
| Max Contact Voltage | 250 VAC 125 VDC |
| Max Contact Current | AC: 3 A DC: 3 A |
| Contact Method | Single |
| Mounting Method | socket |
| Operating Indicator | LED |
| Contacts Configuration | 4PDT |
| Coil Ratings | 200 VAC 50 Hz 4.8 mA 200 VAC 60 Hz 4.2 mA 220 VAC 50 Hz 5.3 mA 220 VAC 60 Hz 4.6 mA |
| Coil Maximum Voltage | 110% (23 ℃) |
| Coil Power Consumption | Approx. 0.9 to 1.3 VA 60 Hz |
| Contact Material | Au clad + Ag alloy |
| Contact Resistance | 50 mΩ max. (Voltage drop method with 5 VDC 1 A) |
| Operating Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Reset Time | 20 ms max. (With rated operating power applied, not including contact bounce) |
| Maximum Operating Frequency | Mechanical: 18000 time/hour Rated load: 1800 time/hour |
| Ambient Temperature Operating | -55 to 60 ℃ (with no freezing or condensation) |
| Ambient Humidity Operating | 5 to 85% |
Overview
The Omron MY4N AC220/240 Relay delivers dependable multi-circuit switching with a closed-type housing , plug-in terminal structure , and a 220/240 VAC coil rating designed for precise control applications. It features a 4PDT contact configuration with a single contact method , supporting 3 A AC/DC maximum contact current and 250 VAC / 125 VDC maximum contact voltage . Built with a 18790 Ω coil resistance , LED operating indicator , fast 20 ms operation/reset time , and durable Au clad + Ag alloy contacts , it ensures stable performance. Capable of high-frequency mechanical operation, it withstands harsh environments from −55 to 60°C, ensuring long-life reliability in industrial control panels.
Datasheet
Omron datasheetmy-datasheet.pdfOther models in this series
Compare MY4N AC220/240 with similar models in the same series. See all 120 models on the MY Series page.
| Model | Mounting Method | Contact Method | Max Contact Voltage | Release Voltage Reset Voltage |
|---|---|---|---|---|
| MY4N AC220/240 (this model) | socket | Single | 250 VAC 125 VDC | — |
| MY4N AC100/110 | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N AC110/120 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N AC12 | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N AC200/220 | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N AC24 | Socket | Single | 250 VAC 125 VDC | 30 % min. |
| MY4N DC100/110 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N DC12 | Socket | Single | 250 VAC 125 VDC | 10 % min. |
| MY4N DC24 | Socket | Single | 250 VAC 125 VDC | 10 % min. |