Image for reference. Refer to the datasheet for exact dimensions.
Omron H7HP-A Counter
Omron H7HP-A Counter with 100–240 VAC input, red backlit LCD, IP66 protection, and dual total/time counting performance.
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Omron H7HP-A technical specifications
| Function | Total Counter, Time Counter |
|---|---|
| Rated supply voltage | 100 to 240 VAC 50/60 Hz |
| Operating voltage range | 85 to 110% of the power supply voltage |
| Power consumption | 6.5 VA max. |
| External power supply | 12 VDC 50 mA |
| Count range | -99999 to 999999 |
| Max. counting speed | 30 Hz/5 kHz (switching) |
| Counter Input mode | Increment/decrement (UP/DOWN (individual input)) |
| Reset system | External and manual reset |
| Input signal | Count 1/start, Count 2/gate, Reset, Key protect |
| No-voltage input (Contact input) | Short-circuit (ON) impedance: 1 kΩ max. Short-circuit (ON) residual voltage: 2 VDC max. Open circuit impedance: 100 kΩ min. |
| Voltage input | Hight level: 9 to 24 VDC (ON voltage) Low level: 5 VDC max. (OFF voltage) Short-circuit (ON) impedance: 1 kΩ max. Open circuit impedance: 100 kΩ min. |
| Display method | 7-segment backlit negative transmissive Red LCD |
| Display Digits | 6 digit |
| Memory backup methods | Method: EEP-ROM, Number of rewite: 200,000 operations min., Store data: 20 years min. |
| External connections | Screw terminal |
| Counter Reset system | External and manual reset |
| Input mode | No-voltage (NPN, contact input)/Voltage input (PNP) selectable |
| Time counter ranges | Cumulative |
| counter Time ranges | 0.1 h to 99999.9 h/1 s to 99 h 59 min 59 s |
| Time counter Set value read selector | ±100 ppm (-10 to +55 ℃) |
| Ambient temperature (Storage) | -10 to 55 ℃ (with no icing) |
| Ambient humidity (Operating) | 35 to 85 % |
| Dielectric withstand voltage | Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min Between power terminals and control input terminals: 2000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between power terminals: 3.0 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
| Noise immunity | Between power terminals: ±1.5 kV Between input terminals: ±480 V square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
| Static immunity | Display: Mulfunction: 8 kV, Destruction: 15 kV Dip switch: Mulfunction: 4 kV, Destruction: 8 kV |
| Vibration resistance | 100 MΩ min. (at 500 VDC) |
| Shock resistance | Destruction: 294 m/s2, 3 times each in 3 axes each directions Malfunction: 196 m/s2, 3 times each in 3 axes each directions |
| Degree of protection | Case front: IP66 Oil-resistant type and NEMA Type 4 (indoors) |
| Case color | Gray smoke (Front: Light gray (Munsell 5Y7/1)) |
| Weight | Approx. 115 g |
Overview
The Omron H7HP-A Counter combines totalizing and time-counting capability with a wide 100 to 240 VAC supply, offering flexibility for industrial automation. It supports 30 Hz and 5 kHz counting speeds, along with UP/DOWN input modes for versatile operation. Its 6-digit red backlit LCD ensures clear visibility, while external and manual reset options add convenience. The unit delivers IP66 oil-resistant protection, excellent noise immunity, and long-term memory retention through reliable EEPROM storage. Manufactured by Omron and listed under Omron Counter products, this model belongs to the Omron H7HP Series .
Datasheet
Omron datasheeth7hp-datasheet.pdfOther models in this series
Compare H7HP-A with similar models in the same series. See all 8 models on the H7HP Series page.
| Model | Rated supply voltage | Power consumption | Display Digits | Function |
|---|---|---|---|---|
| H7HP-A (this model) | 100 to 240 VAC 50/60 Hz | 6.5 VA max. | 6 digit | Total Counter, Time Counter |
| H7HP-AB | 100 to 240 VAC 50/60 Hz | 6.5 VA max. | 6 digit | Total Counter, Time Counter |
| H7HP-AD | 12 to 24 VDC (Ripple 20 % max.) | 0.6 W max. | 6 digit | Total Counter, Time Counter |
| H7HP-ADB | 12 to 24 VDC (Ripple 20 % max.) | 0.6 W max. | 6 digit | Total Counter, Time Counter |
| H7HP-C8 | 100 to 240 VAC 50/60 Hz | 6.5 VA max. | 8 digit | Total Counter, Time Counter |
| H7HP-C8B | 100 to 240 VAC 50/60 Hz | 6.5 VA max. | 8 digit | Total Counter, Time Counter |
| H7HP-C8D | 12 to 24 VDC (Ripple 20 % max.) | 0.6 W max. | 8 digit | Total Counter |
| H7HP-C8DB | 12 to 24 VDC (Ripple 20 % max.) | 0.6 W max. | 8 digit | Total Counter |