IndMALL 2.0 preview — for review only, not indexed by search engines. Links reflect the live IndMALL site; WhatsApp buttons open the real IndMALL enquiry number.

Industrial automation products & suppliers across India

Omron H7CC-A11S Digital Counter

Image for reference. Refer to the datasheet for exact dimensions.

Omron H7CC-A11S Digital Counter

Omron H7CC-A11S Counter with transistor output, 11-pin socket, 100–240 VAC, 10 kHz speed, and 6-digit display for high-speed preset applications.

Brand
Omron
Model number
H7CC-A11S
Series
H7CC Series
Product type
Counters

Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.

Omron H7CC-A11S technical specifications

Power consumptionApprox. 6.8 VA
External power supply12 VDC (±10%), 100 mA (except for H7CC-A8@ models) Refer to Precautions for Correct Use on page 61 for details
Max. counting speed30 Hz (minimum pulse width: 16.7 ms) or 10 kHz (minimum pulse width: 0.05 ms) (selectable) (ON/OFF ratio 1:1) *Common setting for CP1 and CP2
Counter Input modeIncrement (UP), decrement (DOWN), increment/decrement (UP/DOWN A (command input), UP/DOWN B (individual inputs), or UP/DOWN C (quadrature inputs)), UP/DOWN D (command input), UP/DOWN E (individual inputs), UP/DOWN E (quadrature inputs)
Input signalCP1, CP2, reset, and total reset
Prescaling functionYes (0.001 to 99.999)
Decimal point adjustmentRefer to the separate table for tachometer function ratings
ClassificationPreset counter
Configuration• 1-stage preset counter • Total and preset counter
Power supply voltage100 to 240 VAC
Mounting methodFlush mounting or surface mounting
External connections11-pin socket
OutputsContact output (SPDT)
Digits6 digits -99999 to 999999 (-5 digits to +6 digits)
Operating voltage fluctuation range85% to 110% of rated supply voltage (12 to 48 VDC: 90% to 110%)
Auto-zero time/Startup time0.01 to 99.99 s
Sensor waiting timeExternal (minimum reset signal width: 1 ms or 20 ms, selectable), manual, and automatic reset (internal according to C, R, P, and Q mode operation)
Control output• Contact output: 3 A at 250 VAC/30 VDC, resistive load (cosφ=1), Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) • Transistor output: NPN open collector, 100 mA at 30 VDC, Residual voltage: 1.5 VDC max. (approx. 1 V), Leakage current: 0.1 mA max.
Display7-segment, negative transmissive LCD Character height Count value: 10 mm (white) Set value: 6 mm (green)
Memory backupNon-volatile memory (overwrites: 100,000 times min.) that can store data for 10 years min.
Storage temperature range-10 to 55°C (-10 to 50°C if Counter/Tachometers are mounted side by side) (with no icing or condensation)
Operating humidity range25% to 85%
Input modeNo-voltage (NPN) input/voltage (PNP) input (switchable) No-voltage inputs: ON impedance: 1 kΩ max. (Leakage current: 12 mA at 0 Ω) ON residual voltage: 3 V max. OFF impedance: 100 kΩ min. Voltage input: High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
Degree of protectionIEC IP66 for panel surface only and only when Y92S-P6 Waterproof Packing is used
Case colorBlack (N1.5)
Specifications as listed by IndMALL. Confirm against the manufacturer's datasheet before ordering.

Overview

The Omron H7CC-A11S Counter provides dependable 1-stage preset and total counting with a fast-response SPST transistor output, ideal for high-speed control applications. Operating on 100–240 VAC, it uses an 11-pin socket for easy installation and offers selectable 30 Hz or 10 kHz speeds, wide UP/DOWN input compatibility, and external, manual, or automatic reset modes. The 6-digit LCD ensures excellent readability, while non-volatile memory guarantees long-term data retention.

Datasheet

Omron datasheeth7cc-series.pdf

Other models in this series

Compare H7CC-A11S with similar models in the same series. See all 20 models on the H7CC Series page.

H7CC-A11S compared with other models in the series
ModelMounting methodExternal connectionsInput signalClassification
H7CC-A11S (this model)Flush mounting or surface mounting11-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-AFlush mountingScrew terminalsCP1, CP2, reset, and total resetPreset counter
H7CC-A11Flush mounting or surface mounting11-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-A11DFlush mounting or surface mounting11-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-A11SDFlush mounting or surface mounting11-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-A8Approx. 6.8 VA8-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-A8DFlush mounting or surface mounting11-pin socketCP1, CP2, reset, and total resetPreset counter
H7CC-ADFlush mountingScrew terminalsCP1, CP2, reset, and total resetPreset counter
H7CC-ASFlush mounting or surface mounting11-pin socketCP1, CP2, reset 1, and reset 2Preset counter