Omron H3Y-2 AC100-120 10M technical specifications
| Rated power supply voltage | 100 to 120 VAC 50/60 Hz |
|---|---|
| Allowable voltage variable range | 85 to 110% of the power supply voltage |
| Reset voltage | 10% min, of rated supply voltage |
| Number of time ranges | 1 |
| Operation mode | Power ON-delay |
| Control output (Type) | Time-limit: DPDT |
| Control output (Contact output) | Resistive load: 250 VAC 5 A (cosφ=1) Minimum applicable load: 1 mA at 5 VDC (failure level: P) |
| Operating resetting | Time-limit operation/Self-reset |
| Connection method | 8-pin round socket |
| Power consumption | Approx. 1.5 VA (at 120 VAC) |
| Ambient temperature range | Operating: -10 to 50 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
| Accuracy of operating time | ±1% FS max. |
| Setting error | ±10% FS ±50 ms max. |
| Influence of voltage | ±2% FS max. |
| Influence of temperature | ±2% FS max. |
| Insulation resistance | 100 MΩ min. (at 500 VDC) |
| Dielectric strength | Between current carrying terminals and exposed non-current carrying metal parts: 2000 VAC 50/60 Hz 1 min (Terminal screw sections are not excluded) Between operating power circuit and control output: 2,000 VAC 50/60 Hz 1 min Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min |
| Impulse withstand voltage | Between power terminals: 3 kV Between current carrying terminals and exposed non-current carrying metal parts: 4.5 kV |
| Noise immunity | ±1.5 kV square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise) |
| Static immunity | Mulfunction: 4 kV, Destruction: 8 kV |
| Vibration resistance | Destruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 1 hour Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min |
| Shock resistance | Destruction: 1,000 m/s2, 3 times each in 6 directions Malfunction: 100 m/s2, 3 times each in 6 directions |
| Degree of protection | IP40 |
| Case color | Beige |
| Ambient temperature range | Operating: -10 to 50 ℃ (with no icing) Storage: -25 to 65 ℃ (with no icing) |
| Ambient humidity range | Operating: 35 to 85% |
| Reset time | 0.1 s max. (including halfway reset) |
| Life expectancy (relay output) | Electrical: 500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h, Room temperature) Mechanical: 10 million operations min. (under no load at 1,800 operations/h) |
| Weight | Approx. 50 g |
Overview
The Omron H3Y-2 AC100-120 10M Timer is a reliable Power ON-delay timer designed with an allowable voltage variable range of 85 to 110% of the power supply voltage consumption of Approx. 1.5 VA (at 120 VAC). It supports a reset voltage of 1 and offers one selectable time range for consistent timing performance. This Time-limit: DPDT output model operates with Time-limit operation/Self-reset functionality. It features an connecting method and a Beige case color. Manufactured by Omron , listed in Omron Timers , and part of the Omron H3Y-2 Series
Datasheet
Omron datasheeth3y-datasheet.pdfOther models in this series
Compare H3Y-2 AC100-120 10M with similar models in the same series. See all 96 models on the H3Y Series page.
| Model | Allowable voltage variable range | Power consumption | Accuracy of operating time |
|---|---|---|---|
| H3Y-2 AC100-120 10M (this model) | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 0.5S | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS ±10 ms max. |
| H3Y-2 AC100-120 10S | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 120S | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 1S | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 30M | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 30S | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 3H | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |
| H3Y-2 AC100-120 3M | 85 to 110% of the power supply voltage | Approx. 1.5 VA (at 120 VAC) | ±1% FS max. |