Moxa ioLogik R1200 Series technical specifications
| Relay Channels | ioLogik R1214 Series: 6 |
|---|---|
| Analog Input Channels | ioLogik R1240 Series: 8 |
| Analog Output Channels | ioLogik R1241 Series: 4 |
| Isolation | 3k VDC or 2k Vrms |
| Sensor Type | Dry contact, Wet Contact (NPN or PNP) |
| I/O Mode | Voltage/Current |
| Counter Frequency | 2.5 kHz |
| Over-Current Protection | 0.65 A per channel @ 25°C |
| Over-Temperature Shutdown | 175°C (typical), 150°C (min.) |
| Over-Voltage Protection | 45 VDC (typical) |
| Input Voltage | 12 to 48 VDC |
| Operating Temperature | Standard Models: -10 to 75°C (14 to 167°F), Wide Temp. Models: -40 to 85°C (-40 to 185°F) |
| Storage Temperature (package included) | -40 to 85°C (-40 to 185°F) |
| EMC | EN 55032/24 |
| Shock | IEC 60068-2-27 |
Overview
Technical Specifications of Moxa Universal Controllers & I/Os ioLogik R1200 Series: Call us for Moxa Universal Controllers & I/Os ioLogik R1200 Series at the best rates. For analog input channels, ensuring versatile connectivity. The devices are equipped with 3k VDC or 2k Vrms isolation, supporting Voltage/Current I/O modes. The counter frequency is rated at 2.5 kHz with over-current protection of 0.65 A per channel @ 25°C. The input voltage range is 12 to 48 VDC suitable for various applications. Operating temperatures for standard models are Standard Models: -10 to 75°C (14 to 167°F), Wide Temp. Unlock Exclusive Pricing with a Quote for your requirement of Moxa Universal Controllers & I/Os.
Other models in this series
Compare ioLogik R1200 Series with similar models in the same series. See all 4 models on the Moxa Universal Controllers & I/Os Series page.
| Model | I/O Mode | Input Voltage | Analog Output Channels | Sensor Type |
|---|---|---|---|---|
| ioLogik R1200 Series (this model) | Voltage/Current | 12 to 48 VDC | ioLogik R1241 Series: 4 | Dry contact, Wet Contact (NPN or PNP) |
| ioLogik E1200 Series | Voltage/Current | 12 to 36 VDC | ioLogik E1241 Series: 4 | J, K, T, E, R, S, B, N |
| ioLogik E2200 Series | Voltage/Current | 12 to 36 VDC | ioLogik E2240 Series: 2 | J, K, T, E, R, S, B, N |
| ioLogik 2500 Series | ioLogik 2542/2542-T: Voltage/Current | 12 to 48 VDC | — | Dry contact, Wet contact (NPN or PNP) |