Image for reference. Refer to the datasheet for exact dimensions.
Delta DTN8RPTC 8 Channel Temperature Controller
Delta DTN8RPTC 8 channel temperature controller with PID control, RS-485 communication and DIN rail mounting for multi-loop industrial control.
- Brand
- Delta
- Model number
- DTN8RPTC
- Series
- DTN Series
- Product type
- Temperature Controller
Send this enquiry to IndMALL on WhatsApp — the model and page link are filled in. Add the quantity and your company details, and we connect you with the right suppliers.
Delta DTN8RPTC technical specifications
| Channel Number | 8-channel |
|---|---|
| Input Power Supply | DC 24 V, isolated switching power |
| Operating Voltage Range | 90 % - 110 % rated voltage |
| Input Type | Platinum RTD |
| Power Consumption (Max.) | 5.5W |
| Mounting Methods | DIN rail |
| Input Sensor Support | Platinum temperature resistance measurement: Pt100, JPt100, Ni120, Cu50 |
| Sampling Frequency | 0.4 seconds / All input channels |
| Control Methods | PID, ON / OFF |
| Voltage pulse output | Voltage pulse DC 12 V ± 10 %, max. rated output current 20 mA |
| Analog Current Output | 4-20 mA (load impedance ≦ 500 Ω) |
| Analog Voltage | 0-10 V (load impedance ≧ 1,000 Ω) |
| Communication Functions | RS-485 DIP Switch: supports baud rates of 4,800 - 115,200 bps |
| Internal Connection | Features internal connection terminals for 24 V power supply and communication signal transmission |
| Vibration Resistance | 10 ~ 55 Hz, 10 m / s² for 10 mins in X, Y, Z directions |
| Shock Resistance | Max. 300 m / s², 3 times in 3 axes and 6 directions |
| Operating Ambient Temperature | 0 ~ + 50 °C |
| Storage Temperature | - 20 ~ + 65 °C |
| Operating Altitude | < 2,000 m |
| Operating Ambient Humidity | 35 ~ 85 % RH (non-condensing) |
| Pollution Degree | 2 |
| Weight (Max.) | 270 g |
Overview
The Delta DTN8RPTC Temperature Controller is an 8 channel temperature controller designed for multi-loop temperature monitoring and control in industrial automation systems. It supports platinum RTD inputs and operates on a DC 24 V power supply, enabling stable performance across connected process points. It is designed for DIN rail mounting, allowing structured installation within control panels. With RS-485 communication support, it enables integration into centralized monitoring systems. It supports voltage pulse, analog current, and analog voltage outputs, allowing compatibility with different industrial control systems. From an application perspective, the Delta DTN8RPTC aligns with systems that require multi-point temperature monitoring, reliable control output, and stable performance under continuous operation.
Datasheet
Delta datasheetdelta-dtn-datasheet.pdfOther models in this series
Compare DTN8RPTC with similar models in the same series. See all 156 models on the DTN Series page.
| Model | Key specifications |
|---|---|
| DTN8RPTC (this model) | Input Type: Platinum RTD · Mounting Methods: DIN rail · Control Methods: PID, ON / OFF |
| DTE20C | Voltage range: 90% ~ 110% rated voltage · Alarm modes: 12 alarm modes available |
| DTE2DS | Voltage range: 90% ~ 110% rated voltage · Alarm modes: 12 alarm modes available |
| DTE2CT | Voltage range: 90% ~ 110% rated voltage · Alarm modes: 12 alarm modes available |
| DTN8RPTV | Input Type: Platinum RTD · Mounting Methods: DIN rail · Control Methods: PID, ON / OFF |
| DTN8RPT L | Input Type: Platinum RTD · Mounting Methods: DIN rail · Control Methods: PID, ON / OFF |
| DTN8RTCV | Input Type: Thermocouple · Mounting Methods: DIN rail · Control Methods: PID, ON / OFF |
| DTN8RTCC | Input Type: Thermocouple · Mounting Methods: DIN rail · Control Methods: PID, ON / OFF |
| DTN8RTCL | Input Type: Thermocouple · Mounting Methods: DIN rail · Control Methods: PID, ON / OFF |