Danfoss VFD – AC Variable Frequency Drives & Speed Drives
Danfoss VFD devices are used in industrial automation to control the speed and torque of motors by adjusting the input frequency. They are commonly used in conveyors, packaging machines, pumps, and material handling systems where efficient and precise motor control is required. Danfoss is known for delivering reliable and high-performance drive solutions for industrial applications. With strong support from Danfoss VFD Dealers and Distributors , these drives offer smooth operation, stable performance, and long-term durability.
- 7Danfoss series

Danfoss VFD series

Danfoss VFD: HVAC Drive FC 102
Power Range: 1.1 kW to 1.4 MW across various voltage ranges. Temperature Tolerance: Operates from -25°C to +50°C. Energy Efficiency: Enhanced with EC+ Concept. Harmonic Reduction: Low harmonic and 12-pulse drive options.

Danfoss Variable Frequency Drive: FC 103
Power: 1.1 – 800 kW. Voltage: 200-240 V, 380-480 V, 525-600 V, 525-690 V. Max Temp: Efficient up to 50°C. Installation: Cost-effective with scalable RFI filter.

Danfoss VFD Drives: AQUA Drive FC 202
Power: 0.25 kW to 1.4 MW. Voltage: 200-240 V, 380-480 V, 525-600 V, 525-690 V. Harmonic Drive: 132-450 kW (3 x 380-480 V). Features: Energy efficiency, water hammer protection, back-channel cooling.

Danfoss VFD Drive: Vacon® 100 Flow
Power: 0.55 kW to 800 kW. Voltage: 208-240 V, 380-500 V, 525-690 V. Features: Specialized for pump, fan, and compressor applications. Benefits: Easy integration, long lifespan, simple setup.

Danfoss AC Drive: Soft Start Controller MCD 100
Power: 0.1-11 kW (25 A). Voltage: 208-600 V, 24-480 V AC/DC. Features: Compact, adjustable ramp time (0.4–10 sec), adjustable torque (0–85%). Benefits: Space-saving, easy installation, reliable operation.

Danfoss Frequency Drive: Compact Starter MCD 201 and MCD 202
Power: 7.5-110 kW (200 A). Voltage: 200-575 V, 24 V AC/DC, 110-440 V AC. Features: Compact, Ethernet/IP connectivity, built-in bypass. Use: Ideal for industrial pumps, conveyors, fans, mixers, and compressors.

Danfoss Drives: Soft Starter MCD 500
Power: 7.5-850/2400* kW (1600 A). Voltage: 200-690 V, 24 V DC, 110-240 V AC. Use: Ideal for industrial pumps, fans, conveyors, crushers, grinders, mixers, compressors.
Top Danfoss VFD Models
| Model No | Image | Series | Power Rating | Phase | Mains Voltage | Enclosure |
|---|---|---|---|---|---|---|
| FC-051PK18S2E20H3XXCXXXSXXX | 51 | 0.18 KW / 0.25 HP | Single phase | 200 – 240 VAC | IP20 / Chassis | |
| FC-202P7K5T4E20H1XGXXXXSXXXXAXBXCXXXXD | 202 | 7.5 KW / 10 HP | Three phase | 380 – 480 VAC | IP20 / Chassis | |
| FC-102P11KT4E21H2XGXXXXSXXXXAXBXCXXXXDX | 102 | 11 KW / 15 HP | Three phase | 380 – 480 VAC | IP21 / Type 1 | |
| FC-202P7K5T4E20H2XGXXXXSXXXXAXBXCXXXXDX | 202 | 7.5 KW / 10 HP | Three phase | 380 – 480 VAC | IP20 / Chassis | |
| FC-103P22KT4E20H1XGXXXXSXXXXAXBXCXXXXDX | 103 | 22 KW / 30 HP | Three phase | 380 – 480 VAC | IP20 / Chassis |
About Danfoss VFD
Enclosure
51 0.18 KW / 0.25 HP Single phase 200 – 240 VAC IP20 / Chassis FC-202P7K5T4E20H1XGXXXXSXXXXAXBXCXXXXD 202 7.5 KW / 10 HP Three phase 380 – 480 VAC IP20 / Chassis FC-102P11KT4E21H2XGXXXXSXXXXAXBXCXXXXDX 102 11 KW / 15 HP Three phase 380 – 480 VAC IP21 / Type 1 FC-202P7K5T4E20H2XGXXXXSXXXXAXBXCXXXXDX 202 7.5 KW / 10 HP Three phase 380 – 480 VAC IP20 / Chassis FC-103P22KT4E20H1XGXXXXSXXXXAXBXCXXXXDX 103 22 KW / 30 HP Three phase 380 – 480 VAC IP20 / Chassis At IndMALL, we offer a wide range of Danfoss VFD, These drives are perfect for different machines, like pumps and compressors.
Danfoss VFD FAQs
What is Danfoss VFD?
Danfoss VFDs control the speed of electric motors by varying input frequency and voltage. Danfoss offers a broad range of VFDs for different applications. Their drives are known for reliability, energy efficiency, and advanced control features. Danfoss AC Drives are used in various industries like HVAC, water treatment, and manufacturing.
What is the efficiency of VFD Danfoss?
The efficiency of the Danfoss variable frequency drive typically ranges above 95%, depending on the model and load conditions. This high efficiency leads to significant energy savings. Danfoss Variable frequency drives optimize motor control, minimizing energy consumption. However, actual efficiency can vary, so always refer to the specific model’s technical specifications.
What are Danfoss drives used for?
Danfoss makes drives, specifically VFDs. VFDs control the speed of electric motors. Danfoss drives adjust motor speed by changing voltage and frequency. They’re used in pumps, fans, conveyors, and more. Danfoss drives help machines work efficiently and save energy.
Why VFD is used in compressor?
VFD stands for Variable Frequency Drive. Compressors sometimes need different speeds. VFDs help adjust the compressor’s speed by controlling its motor. This provides energy savings and smooth operation. Using VFDs, compressors can work efficiently and last longer.
What does Danfoss drives do?
Danfoss makes drives, also known as VFDs. VFDs control the speed of electric motors. Danfoss drives change the motor’s voltage and frequency. This lets machines like pumps and fans work efficiently. Using Danfoss drives helps save energy and improve performance. Choose IndMALL for Danfoss VFD or Danfoss AC Drives and reach out to us quickly.
Need Danfoss VFD?
Send the model number, quantity and your company details to IndMALL on WhatsApp at +91 79955 44066. We connect you with the right suppliers.