Beckhoff BK2020 technical specifications
| Number of Bus Terminals | 64 (255 with K-bus extension) |
|---|---|
| Max. number of bytes fieldbus | 512 byte input and 512 byte output |
| Configuration possibility | via KS2000 or the controller |
| Data transfer rates | 2.5 Mbaud |
| Bus interface | 2 x standard fiber-optic connector Z1000 (plastic fiber), Z1010 (HCS fiber) |
| Data transfer medium | fiber-optic conductor: APF (plastic) fiber (1,000 µm) or HCS fiber (200 µm) |
| Power supply | 24 V DC (-15%/+20%) |
| Input current | 70 mA + (total K-bus current)/4, 500Â mA max. |
| Starting current | approx. 2.5 x continuous current |
| Recommended fuse | ≤ 10 A |
| Current supply K-bus | 1750 mA |
| Power contacts | max. 24 V DC/max. 10 A |
| Electrical isolation | 500 V (power contact/supply voltage) |
| Distance between stations | 45Â m for APF fiber, 300Â m HCS fiber |
| Data transfer time | 0.26 ms in the case of 10 modules for 32 bit inputs and outputs each (without K-bus run-time) |
| Weight | approx. 150 g |
| Operating temperature | 0...55°C |
| Storage temperature | -25...+85°C |
| Relative humidity | 95%, no condensation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/variable |
| Approvals/markings | CE, CCC, UL, ATEX, IECEx |
| Ex marking | ATEX: II 3 G Ex ec IIC T4 GcIECEx: Ex ec IIC T4 Gc |
| Housing - Design form | compact terminal housing with signal LEDs |
| Housing - Material | polycarbonate |
| Housing - Dimensions (W x H x D) | 51 mm x 100 mm x 69 mm |
| Housing - Installation | on 35 mm DIN rail, conforming to EN 60715 with lock |
| Housing - Side by side mounting by means of | double slot and key connection |
| Housing - Marking | labeling of the BZxxxx series |
| Housing - Wiring | solid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver |
| Housing - Connection cross-section | s*: 0.08...2.5 mm²,st*: 0.08...2.5 mm²,f*: 0.14...1.5 mm² |
| Housing - Stripping length | 8...9 mm |
| Housing - Current load power contacts | Imax: 10 A |
| Digital peripheral signals | 1,020 inputs/outputs |
| Analog peripheral signals | 128 inputs/outputs |
Overview
Beckhoff Bus Coupler BK2020 connects fieldbus systems with Bus Terminals using fiber-optic technology, delivering reliable data transfer for scalable industrial automation. The 24 V DC power supply with a maximum input current of 500 mA supports stable operation, while 500 V electrical isolation provides safety in industrial environments. With a 1750 mA K-bus current supply , the BK2020 can manage 1,020 digital signals and 128 analog signals efficiently. The BK2020 Bus Coupler is widely applied in factory automation, robotics, material handling, and process control systems requiring long-distance, high-speed data communication. Request a call back today to receive technical guidance tailored to your automation project.
Other models in this series
Compare BK2020 with similar models in the same series. See all 8 models on the Beckhoff Bus Coupler page.
| Model | Approvals/markings | Data transfer rates | Number of Bus Terminals | Operating temperature |
|---|---|---|---|---|
| BK2020 (this model) | CE, CCC, UL, ATEX, IECEx | 2.5 Mbaud | 64 (255 with K-bus extension) | 0...55°C |
| BK2000 | CE, CCC, UL, ATEX, IECEx | 2.5 Mbaud | 64 | 0...55°C |
| BK3100 | CE, CCC, UL, ATEX, IECEx, DNV GL | automatic detection up to 12 Mbaud | 64 | 0...55°C |
| BK3120 | CE, CCC, UL, ATEX, IECEx, DNV GL, cFMus | automatic detection up to 12 Mbaud | 64 (255 with K-bus extension) | -25...+60°C |
| BK3150 | CE, CCC, UL, ATEX, IECEx | automatic detection up to 12 Mbaud | 64 (255 with K-bus extension) | -25...+60°C |
| BK3520 | CE, CCC, UL, ATEX, IECEx | automatic detection up to 12 Mbaud | 64 (255 with K-bus extension) | 0...55°C |
| BK4000 | CE, CCC, UL, ATEX, IECEx | 500 kbaud | 64 | 0...55°C |
| BK4020 | CE, CCC, UL, ATEX, IECEx | 500 kbaud | 64 (255 with K-bus extension) | 0...55°C |